Speed
Connector
Duplex
Cable Type
Wiring Standard
Maximum Distance
Isolation
a
Auto-negotiating.
b
Shielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
5.5

Operating Environment

The RUGGEDCOM RSG909R is rated to operate under the following environmental
conditions.
Ambient Operating Tempera-
ture
Ambient Storage Temperature
Ambient Relative Humidity
Maximum Altitude
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
b
Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM
SFP Transceivers Catalog for SFP temperature ratings.
c
Non-condensing.
5.6

Mechanical Specifications

Weight
Ingress Protection
RUGGEDCOM RSG909R
Installation Manual, 02/2020, C79000-G8976-1388-09
10 Mbps Ports
IEC
 
IEC
ü
a
10/100/1000Base-TX
RJ45
a
FDX/HDX
b
> CAT 5
c
TIA/EIA T568A/B
d
100 m (328 ft)
e
1.5 kV
a b
c
5.4 Copper Ethernet Port Specifications
100 Mbps
1000 Mbps
Ports
Ports
ü
ü
ü
ü
-40 to 85 °C (-40 to 185 °F)
-40 to 85 °C (-40 to 185 °F)
5% to 95%
2000 m (6562 ft)
2.4 kg (5.3 lbs)
IP40
Technical Specifications
Description
Media Redundancy Protocol
(MRP)
High-Availability Seamless Re-
dundancy (HSR), Parallel Redun-
dancy Protocol (PRP)
31