3. If the bracket has been temporarily fastened to the transom, remove it. Apply a
marine sealant to the threads of the three #10 1-1/4" self-tapping screws to pre-
vent water seeping into the transom. Screw the bracket to the hull. Do not tighten
the screws completely at this time.
4. Repeat step 1 to ensure that the angle of the sensor is correct.
Note: Do not position the sensor farther into the water than
necessary to avoid increasing drag, spray, and water noise and reducing boat
speed.
5. Using the vertical adjustment space on
the bracket slots, slide the sensor up or
down to provide a projection of 3 mm
(1/8"). Tighten the screws.
How to attach the sensor to the bracket
1. If the retaining cover near the top of the brack-
et is closed, open it by depressing the latch
and rotating the cover downward.
2. Insert the sensor's pivot arms into the slots
near the top of the bracket.
3. Maintain pressure until the pivot arms click
into place.
4. Rotate the sensor downward until the bottom
snaps into the bracket.
5. Close the retaining cover to prevent the
accidental release of the sensor when your
boat is underway.
1. MOUNTING
Cable cover
Cable clamp
Hull projection 3 mm (1/8")
Step 1
Step 2
Latch
Pivot
arm
Retaining
cover
Step 3
Step 4
50 mm (2")
Slot
1-13