Valor Legend G4 Series Installation & Owner's Manual page 16

Direct vent gas insert fireplace 780kn (natural gas) & 780kp (propane gas)
Table of Contents

Advertisement

OWNER'S
INFORMATION
To refi t the window:
DANGER
!
The window unit must be correctly installed,
fastened and sealed after servicing or serious
bodily injury and/or damage to the appliance
may result.
To ensure a safe operation:
• Double-check that the bottom of the window
frame is correctly installed in the bottom
support railing;
• Verify that the levers are hooked properly to
the window tabs then;
• Pull out the top of the window and release it
to insure the springs return it;
• Ensure the window is sealed before operation.
WARNING
!
Failure to install the window correctly can
leak carbon monoxide, aff ect the performance
of the fi replace, damage components, cause
overheating resulting in dangerous conditions.
Damage caused by incorrect window installa-
tion is not covered by the Valor warranty.
1. Place the window in its bottom
railing and push its top against
the fi rebox. Ensure to remove
any coal particles in the
railing before installing the
window.
16
Servicing & Maintenance
2. While you hold it, unhook the side levers from the
trim supports and hook them into the window tabs.
3. Pull out the top of the window and release it to
ensure the springs return it.
4. Apply firm hand pressure around the window
frame to ensure the window is sealed tight
against the firebox.
5. If the Hot Glass Warning plate has been removed
from the front lower corner of the window,
reinstall it by sliding it between the glass and
the frame as indicated.
Window
frame
6. Reinstall the access side doors to the fi replace.
7. Rehook the front trim fi tted with the barrier screen.
Bottom
railing
F O R S A F E T Y P U R P O S E , ensure the
barrier screen is re-installed on the fi replace
front after maintenance.
Safety warning plate