Grounding scheme (example)
Ex zone
B_00304
Part / workstation
Pump
Product tank
Conveyor
Booth
Spraying stand
Safe operation of the IceBreaker pump is only guaranteed with a grounding
connection. Connect all grounding cables using a short and direct route.
Procedure:
1. Screw on grounding cable with eyelet.
2. Clamp the grounding cable clip to a grounding connection on site.
3. Ground the product tank to an on-site grounding connection.
4. Ground the other parts of the system to an on-site grounding
connection (16 mm2; AWG 6).
Ex zone
All devices and equipment must be suitable for use in potentially explosive areas.
All paints, flushing agents and waste tanks have to be electrically conductive.
All tanks must be grounded.
ORDER NUMBER DOC 2340282
Product
tank
Floor, static dissipative
Cable cross section
4 mm2; AWG 12
6 mm2; AWG 10
16 mm2; AWG 6
16 mm2; AWG 6
16 mm2; AWG 6
IceBreaker 150-300 cm
Conveyor
Work piece
R max < 1 MΩ
Spraying stand
3
B_05443
34