Corner Installation; Wall And Ceiling Clearances; Mantel Clearances; Hearth Requirements - Vermont Castings INDVRBDSB Installation And Operating Instructions Manual

Table of Contents

Advertisement

Intrepid® Direct Vent - Rear Vent Gas Heater
Parallel Installation:
Minimum Clearance and Flue Centerline
18³⁄₄"
(476 mm)
4"
(102 mm)
Figure 3 - Parallel Installation, minimum back and side clearance.

Corner Installation:

Minimum Clearance and Flue Centerline
7¹⁄₂"
ST947
(190 mm)
Intrepid
Parallel installation
Max. Vent
6/07
Length
24" (610 mm)
2"
(51 mm)
Figure 4 - Corner installation, minimum corner clearance and flue
centerline.
St948

Wall and Ceiling Clearances

rear corner specs
6/07
4"
(102 mm)
Sidewall/
Trim
Figure 5 - Alcove and ceiling clearances.
St949
3-90-20306761
Wall/Ceiling clearances
Max. Vent
Length
C L
24" (610 mm)
2¹⁄₂"
(64 mm)
4"
(102 mm)
2" (51 mm)
9"
(230 mm)
Max. Mantel
Width
Refer to
Fig. 6
(63 mm)
Rear Wall
Vermont Castings • Intrepid DV Owner's Manual_R3 • 12/16
Combustible
Mantel or
Trim Materials
B
3" (75mm) Min.
A (Maximum)
9" (230 mm)
7-1/2" (190 mm)
6" (152 mm)
4-1/2" (114 mm)
3" (76 mm)
1-1/2" (38 mm)
A = Depth of Mantel and/or Top Trim
B = Height from Top of Heater
Figure 6 - Mantel / top trim clearances.

Hearth Requirements

The Intrepid Heater must be installed on rigid flooring. When
the heater is installed directly on any combustible surface
other than wood flooring, a metal or wood panel extending the
full width and depth of the unit must be used as the hearth.
There are no other hearth requirements.
2¹⁄₂"

Mantel Clearances

A
B (Minimum)
10-1/2" (270 mm)
ST382
9" (230 mm)
Pinnacle
7-1/2" (190 mm)
mantel clearances
6" (152 mm)
6/13/00 djt
4-1/2" (114 mm)
3" (76 mm)
Noncombustible
Materials
7