Maintenance; Disposal; Technical Data - Cedes TOF/Start-EA Installation And Operation Manual

Table of Contents

Advertisement

TOF/Start-EA

14. Maintenance

Although the TOF/Start-EA does not need regular
maintenance, a periodical functional check is strongly
recommended as follows:
 Check the mounting position and detection area of the
sensor.
 Clean the optical window with a soft towel and a little
soapy water.
NOTICE
Damage to the optical window
 Never
use
mechanically abrasive towels or highpressure
water to clean the sensors.

15. Disposal

The TOF/Start-EA should only be replaced if a similar
protection device is installed. Disposal should be done
using the most up-to-date recycling technology according
to local regulations and laws. There are no harmful
materials used in the design and manufacture of the
sensor. Traces of such dangerous materials may be found
in the electronic components but not in the quantities that
are harmful.

16. Technical data

Optical
Detection area
- Length
- Width
Mechanical
Dimensions (w × h × l)
Housing material
Housing color
Enclosure rating
Temperature range
Electrical
Supply voltage U
SP
Current consumption
at 24 VDC
Output
Max. response time
• Area without cross-traffic < 1 m 200 ms
• Area with cross-traffic > 1 m
Min. switching time
Power-on time
© CEDES | V 1.0
any
solvents,
cleaners
Min. 0 ... 400 mm
Max. 0 ... 2,000 mm
Min. 0 ... 400 mm
Max. 0 ... 2,000 mm
57 × 34 × 44.5 mm
Polycarbonate
Black
IP65
−20 °C ... +65 °C
24 VDC ±20%
50 mA
(peak max. 0.5 A)
PNP/NPN (push-pull)
400 ms
200 ms
1 s
Connection cable and electrical connection
Sensor
Length
Connection
Diameter
Material
Plug color
Connection cable
Length
or
Connection
Diameter
Material
Plug color
Wires
brown
blue
black
white
gray
green
General
Eye safety
EMC emission
EMC immunity
Vibration
Shock
RoHS
Certificate
English
0.25 m
M8, 6-pin
Ø 4.2 mm
PVC, black
Blue
2 m
(other lengths on request)
M8, 6-pin
Ø 4.2 mm
PVC, black
Blue
AWG26
U
SP
GND (0 V)
Output
Not connected
Selectable output logic
Not connected
EN 62471:2008
EN 61000-6-3:2007
EN 12015:2014
EN 61000-6-2:2005
EN 12016:2013
IEC 60068-2-6:2007
IEC 60068-2-27:2008
2011/65/EU