Led Signal; Trouble Shooting; Maintenance; Disposal - Cedes TOF/Spot Installation And Operation Manual

Hide thumbs Also See for TOF/Spot:
Table of Contents

Advertisement

Available languages

Available languages

TOF/Spot

12. LED signal

LED status
Description
LED off
No power
LED dimmed red
No object detected
LED bright red
Object detected or test active
LED blinking
Distance setting active
(C and T type only)

13. Trouble shooting

Status
LED off
Object in the
safeguarded area and
LED dimmed red
No object in the
safeguarded area and
LED bright red
The output doesn't
switch after
starting test
The output doesn't
switch back after ending
of test
If the problem persists, please contact your local CEDES
representative (www.cedes.com).
12
Action
 Check supply power
 Check electrical
connections
 Check distance setting
 Check alignment
 Check electrical
connections
 Check distance setting
 Check alignment
 Is an object in the
detection area?
 Check electrical
connections
 Sensor doesn't see a
background
 Is an object in the
detection area?
 Check distance setting

14. Maintenance

Although
the
TOF/Spot
maintenance, a periodical functional check is strongly
recommended as follows:
 Check the mounting position and detection area of the
sensor
 Clean the optical window with a soft towel and a little
soapy water
nOTICE
Damage to the optical window
 Never
use
or mechanically abrasive towels or
highpressure water to clean the sensors.

15. Disposal

The TOF/Spot should only be replaced if a similar
protection device is installed. Disposal should be done
using the most up-to-date recycling technology according
to local regulations and laws. There are no harmful
materials used in the design and manufacture of the
sensor. Traces of such dangerous materials may be found
in the electronic components but not in the quantities that
are harmful.

16. Product Label

Each TOF/Spot and TOF/Spot-S is labelled as below.
It contains following information:
Figure 27: Product label - TOF/Spot (standard version)
Figure 28: Product label - TOF/Spot-S (safety version)
Lot no.:
yymmdd: year (2 digits), month, day
mmmmmmmm: manufacturing job number
eeeee: employee number responsible for final test
cccccc: incremental number
English
does
not
need
regular
any
solvents,
cleaners
© CEDES | V 2.0

Advertisement

Table of Contents
loading

Table of Contents