Cedes TOF/Spot Installation And Operation Manual

Hide thumbs Also See for TOF/Spot:

Advertisement

Quick Links

TOF/Spot
Installation and Operation Manual
RoHS
CEDES AG is certified according to ISO 9001:2015
English
Pages
2 – 12
Original version
113 009 | 200512 | V 4.0

Advertisement

Table of Contents
loading

Summary of Contents for Cedes TOF/Spot

  • Page 1 TOF/Spot Installation and Operation Manual RoHS CEDES AG is certified according to ISO 9001:2015 English Pages 2 – 12 Original version 113 009 | 200512 | V 4.0...
  • Page 2: Table Of Contents

    Installation Mounting of snap-in housing Electrical connection Start-up Timing diagrams LED signal Trouble shooting Maintenance Disposal Product Label Technical data Dimensions CEDES AG reserves the right to modify or change technical data without prior notice. © CEDES | V 4.0...
  • Page 3: Safety Information

     Do not use the sensor if it is damaged in any way.  Keep the instruction manual on site. Safety messages categories The TOF/Spot should only be installed by authorized and fully trained personnel! The installer or system integrator is Warning of serious health risks fully responsible for the safe integration of the sensor.
  • Page 4: Introduction

    TOF/Spot English Introduction Type description TOF/Spot - a - bb - c - d - e, ff, range The TOF/Spot is a compact yet powerful single-spot measuring system with the widest range of application TOF/Spot version Standard possibilities. It uses Time-of-Flight technology (TOF) to...
  • Page 5: Tof/Spot Product Overview

    0.2 m (0.7 ft) cannot be guaranteed. The TOF/Spot features a detection area of 20 mm × 20 mm at 2 m (0.79 in × 0.79 in at 6.5 ft) range. It reads the correct distance and switches the output reliably for objects covering the full beam size (detection area).
  • Page 6: Alignment

    Illumination size of the TOF/Spot As the illumination size is bigger than the detection size, at 2 m (6.5 ft) range, the TOF/Spot needs at least 20 cm (7.87 in) space to the next sensor to avoid interference. © CEDES | V 4.0...
  • Page 7: P Type (Preset)

    0.2 m and 3 m (0.7 ft and 10 ft) using the potentiometer the calibration is finished, the sensor stops blinking and located at the rear of the sensor. stays red for about 30 s. Now the wiring of the TOF/Spot has to be adjusted according to the electrical connections Important: (brown wire to U and blue wire to GND).
  • Page 8: I Type (Initialized)

    Release Universal output (relays output) Calibration Check & operation The TOF/Spot features a universal (relays) output. With Figure 15: Configuration T type with the teach-in button the help of the logic selector, the output signal can be configured according to the controller requirements for Important: “normally open”...
  • Page 9: Installation

    TOF/Spot English Electrical connection Dynamic universal output The TOF/Spot features a universal (relay) output. In case There are different possibilities according to supply power of the dynamic universal output this relay will switch with and output chosen. a frequency of 1kHz. With the logic selector the signal can...
  • Page 10: Timing Diagrams

    Table 2: General value table 12. LED signal LED status Description LED off No power LED dimmed red No object detected LED bright red Object detected LED blinking Distance setting active (C and T type only) © CEDES | V 4.0...
  • Page 11: Trouble Shooting

    15. Disposal The TOF/Spot should only be replaced if a similar protection device is installed. Disposal should be done using the most up-to-date recycling technology according to local regulations and laws. There are no harmful materials used in the design and manufacture of the sensor.
  • Page 12: Technical Data

    Sensor Length 0.25 m Connection Screwable, M8, 6-pin Diameter Ø 4.2 mm Material PVC, black Plug color Blue CEDES AG, Science Park | CH-7302 Landquart Phone: +41 81 307 2323 | Fax: +41 81 307 2325 | info@cedes.com | www.cedes.com...

This manual is also suitable for:

Tof/spot-s

Table of Contents