12. Blanking

The TOF/Start-EA features a blanking function. The TOF/
Start-EA triggers the output when objects are dynamic
(moving) within the detection field. Static objects within the
detection field will be ignored and blanked out (after 30
seconds). This covers with objects that are already present
at power up (i.e. bollards).
Start-up:
LED dimmed
Figure 14: Active blanking - start-up sequence with i.e. bollards.
Figure 15: After start-up the bollards are blanked out
from the detection field.
Active blanking:
Figure 16: The detection field is free.
8
LED dimmed
LED bright
LED dimmed
LED dimmed
Figure 17: A static object is placed in the detection field
(i.e a trash bag). The object will be detected.
Figure 18: After 30 s the static object will be blanked out and
the TOF/Start-EA continues its operation with the new
geometry of the detection field.

13. Trouble shooting

Status
LED off
Object in the
safeguarded area and
LED dimmed red
No object in the
safeguarded area and
LED bright red
LED bright
If the problem persists, please contact your local CEDES
representative (www.cedes.com).
English
LED bright
LED dimmed
LED dimmed
Action
 Check supply power
 Check electrical
connections
 Check distance setting
 Check electrical
connections
 Check distance setting
© CEDES | V 1.0