Led Signals; Cross-Traffic - Cedes TOF/Start-EA Installation And Operation Manual

Table of Contents

Advertisement

TOF/Start-EA

10. LED signals

The red LED provides the sensor's status. The respective
LED is dimmed when the power is OK and the detection
field is free. The LED glows bright when an object is
detected and the respective output triggered. The LED is
visible from the front.
LED dimmed
Figure 9:
LED indicator
LED status
LED off
LED dimmed red
LED bright red

11. Cross-traffic

The TOF/Start-EA features a cross traffic detection
function. If a person moves towards the door entrance
area, the TOF/Start-EA triggers the output. If the
person only moves across the door entrance area, the
TOF/Start-EA recognizes that the person does not wish to
use the door and does not trigger the output.
Important:
The cross-traffic activation zone begins at a 1 meter
distance from the sensor.
Figure 10: Detection field free; person moves towards the
door entrance area. LED status is dimmed.
© CEDES | V 1.0
LED dimmed
y
Area
without
LED bright
cross-traffic
Description
No power
No object detected
Object detected
LED dimmed
y
LED dimmed
Area
y
without
cross-traffic
Area
without
cross-traffic
Figure 11: Person is detected entering detection area, moving
towards the door entrance area. LED status is
bright.
Figure 12: Detection field free; Person moves to cross the
door entrance area. LED status is dimmed.
Figure 13: Sensor recognizes the person is moving cross the
door entrance. LED status remains dimmed
à no output switched.
English
LED bright
y
Area
without
cross-traffic
LED dimmed
y
Area
without
cross-traffic
LED dimmed
y
LED bright
Area
y
without
cross-traffic
Area
without
cross-traffic
7