TOF/Start-EA
Important:
 The scale is not printed on the sensor. The
potentiometer can be adjusted linearly from 0.4 m to
2.0 m; see Figure 3 below.
 Take a small screw driver and turn the potentiometer
to the required position.
Area without cross-traffic
1.2 m
0.8 m
0.4 m
x = min. 400 ... max. 2000
Figure 3:
Detection field using potentiometer
Parameter
Value
Operating range
Min.: 0 ... 400 mm
x-axis
Max.: 0 ... 2,000 mm
Operating range
Min.: 0 ... 400 mm
y-axis
Max.: 0 ... 2,000 mm
Aperture angle
70°
Table 1:
Parameter - detection field

6. Installation

Important:
The TOF/Start-EA must be mounted at a minimum 10°
mounting angle to the ground.
10°
Figure 4:
Mounting angle of TOF/Start-EA
© CEDES | V 1.0
1.6 m
y-axis
2 m
1.2 m
1.6 m
0.8 m
0.4 m
2 m
x-axis
(all dimensions in mm)
7. Input / Output description and
electrical connection
Generally the TOF/Start-EA has one output that is triggered
if the detection field is interrupted. For this purpose, a
push-pull output is used. With the logic selector (gray wire,
Figure 6), the logic of the output signal can be configured
for "HIGH" on object or "LOW" on object operation
(Figure 5), according to the controller requirements.
The logic selection is performed during start-up.
Logic selector connected to U
SP
U
SP
Output
0 V
Logic selector connected to GND (0 V)
U
SP
Output
0 V
Figure 5:
Output (PNP/NPN) logic
U
SP
TOF/Start-EA
Output
n.c.
GND (0 V)
n.c.
Selectable output logic
n.c. = not connected and isolated
Figure 6:
Connection diagram

8. Start-up

1. Switch on mains and power up.
2. Check if LED lights up.
3. Check the distance setting and the reaction of the
sensor, including the status LED, by placing an object
into the detection area at different heights and widths.
English
brown
black
green
blue
white
gray
5