Cedes TLS 600 Installation And Operation Manual

Cedes TLS 600 Installation And Operation Manual

Hide thumbs Also See for TLS 600:

Advertisement

Quick Links

TLS 600
Installation and Operation Manual
RoHS
CEDES AG is certified according to ISO 9001: 2008
English
Pages 2 - 12
111 189 | 130208 | V 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Cedes TLS 600

  • Page 1 TLS 600 Installation and Operation Manual RoHS CEDES AG is certified according to ISO 9001: 2008 English Pages 2 - 12 111 189 | 130208 | V 1.0...
  • Page 2: Table Of Contents

    11. LED signals 12. Sensor recalibration 13. Troubleshooting 14. Maintenance 15. Disposal 16. Technical data 17. Dimensions 17.1 Mounting bracket scaled plan © CEDES | V 1.0 CEDES AG reserves the right to modify or change technical data without prior notice.
  • Page 3: Safety Information

    Do not use the sensor if it is damaged in any way. Keep the instruction manual on site. 3.1 Safety message categories The TLS 600 should only be installed by authorized Warning of serious health risks and fully trained personnel! The installer or system...
  • Page 4: Introduction

    DO Dark on and/or objects. At a typical mounting height of 2.3 m (7.5 ft), a single TLS 600 provides a Output type 1 m × 0.3 m (3.3 ft × 1 ft) monitored area, providing reliable door-opening for sliding doors, including telescopic sliding doors.
  • Page 5: Overview

    High contrast between objects and background results in high sensitivity. Figure 4: TLS 600 in vertical mounting monitoring the Figure 3: TLS 600 in angeled mounting monitoring the closing area of a sliding door approach area of a sliding door 5.1 Delivery package...
  • Page 6: Tls 600 Product Overview

    Figure 8: Configuring the TLS 600 P-type (in seconds) Adjusting screw Optical window 6.1 Background influence TLS 600 has a maximal operating range of 4 m 5.3 Detection area dimensions (13 ft) on Kodak white. However, different floor materials and colors influence the effective operating The detection area dimensions of the sensor depend range.
  • Page 7: Installation

    2. Turn the adjusting screw to vertical position using a screwdriver. Figure 12: Snapping on the TLS 600 mounting bracket 6. Set the alignment of the TLS 600 by turning the adjusting screw until the correct angle is set. Figure 9: Turn the adjusting screw to vertical position 3.
  • Page 8: Electrical Connection

    Figure 14: TLS 600 connection diagram 8.1 Semiconductor output 8.2 Test input The TLS 600 is available as a PNP or NPN version TLS 600 performs a test cycle as follows: The with either a dark-on (DO) or light-on (LO) type.
  • Page 9: Timing Diagram

    No object HIGH Test input Test active HIGH Output PNP-LO / NPN-DO HIGH Output PNP-DO / NPN-LO Figure 15: TLS 600 timing diagram Time Value Value Power-up time < 150 ms Output HIGH ≥ U - 4 V Output LOW <...
  • Page 10: Led Signals

    TLS 600 11. LED signals 13. Troubleshooting The TLS 600 uses a red LED to indicate its status. Sensor status Action  Check the sensors Object is in LED glows brightly Object detected detection capability in detection area but LED glows softly...
  • Page 11: Technical Data

    • brown (10 ... 30 VDC) • blue GND (0 V) • black Output • white Test input General EMC emission EN 61000-6-3:2007 EMC immunity EN 61000-6-2:2005 Shock EN 60068-2-27:2009 Vibration EN 60068-2-6:2008 RoHS 2011/65/EU Certificate © CEDES | V 1.0...
  • Page 12: Dimensions

    7.5 mm (0.3 in) Ø 4.2 mm (0.16 in) Ø 3.6 mm (0.14 in) Ø 4.2 mm (0.16 in) CEDES AG, Science Park | CH-7302 Landquart Phone: +41 81 307 2323 | Fax: +41 81 307 2325 | info@cedes.com | www.cedes.com...

Table of Contents