Installation and operation manual
Content
1.
1.1.
1.2.
Features ................................................. 3
1.3.
2.
2.1.
Dimensions ............................................ 3
2.2.
Setup ..................................................... 4
2.3.
3.
.............................................................. 5
3.1.
3.2.
3.3.
Test Input ............................................... 5
4.
4.1.
Start-Up ................................................. 5
4.2.
LED status .............................................. 5
5.
5.1.
Maintenance .......................................... 6
5.2.
Disposal................................................. 6
6.
7.
8.
8.1.
1. Introduction
The TLS 500 measures the reflection from objects
compared with background reflection. Any change in
the values is detected as an object and the output
switches.
1.1. Functionality
After switching on the TLS 500, it calibrates a
background measurement and saves this as a
reference value. When an object enters the detection
area, the reflection value changes.
The bigger the difference in light reflection between
the object and the background, the easier it is to
detect said object. High sensitivity comes from a
clear contrast between a detectable object and the
background: For example curtain, cloth, rubber,
asphalt, wood, concrete, earth, terracotta, cardboard
in comparison to people.
Poor sensitivity comes from a reflecting background
like marble, metal, glass, bright objects on bright
background, dark objects on dark background and
no background (the sensor does not see the floor).
1.2. Features
Intelligent, infrared-based diffuse-reflective sensor
Excellent detection capability
PNP or NPN output, light on or dark on available
For indoor and outdoor applications
Small and sleek design
Plug-and-play and easy mounting
Operating range up to 6 m
Insensitive to direct sunlight up to 100,000 Lux
© CEDES/May 2011
Test input (N-, P-type)
1.3. Type definition
Figure 1: Type definition
2. Installation
2.1. Dimensions
www.cedes.com
TLS 500
Output logic:
LO (light on)
DO (dark on)
Output signal:
PNP
NPN
Types:
N = Standard
P = Adjustment of recalibration time
VR = Adjustment of range
3