4. Main functions

Adjusting the trigger level and gap between different
sensors is highly important. Following these simple
guidelines will enable perfect detection with the TPS family.
With separately adjustable trigger levels on each beam,
the TPS can be used for different detection heights. The
operation range is between 0.1 m to 2 m from the device.
The trigger level can be adjusted manually from 0.3 m up
to 2 m in order to determine the preferred detection range.
Integrated status LED
Beam 1 trigger level adjustment
Beam 2 trigger level adjustment
4 holes to mount the windows on housing
4 holes to mount the housing
Figure 4:
Operating range and trigger levels of the device
S
Maximum operation / trigger level
total
S
Minimal operation level
omin
S
Trigger level set by factory
factory
S
Minimal trigger level
tmin
A 1 / A2
Trigger level increase
A 1 / A2
Trigger level decrease
Example for trigger adjustment:
The TPS device is mounted at the top to detect objects from
above. To detect the higher object, the trigger level has to
be set between the height of two objects.
The trigger level can be calculated according to
S
trigger
4
Manually adjustable
trigger level from
0.3 ... 2 m
A1
A2
= S
– S
mount
height
Figure 5:
Example for triggering the TPS device

5. Installation

 Be sure to turn off power supply when carrying out
electrical work.
 Clearly mark that this device is out of service.
There are one flush and two surface mounting solutions.
Distances from wall, doors and/or other obstacles must
be considered. The application of multiple (adjacent) TPS
sensors requires a minimum gap between the devices.
This gap is needed to avoid any interference between
neighboring sensors.
IMPORTANT
 Every device needs to be separately connected to
the corresponding control device. For electrical
connection, see Figure 10.
S
wall
2.0 m
0.1 m
1.0 m
0.3 m
Figure 6:
Spacing for TPS front view (left) side view (right)
S
Spacing to wall
wall
S
Spacing to next TPS
gap
S
Spacing to door
door
Objects in the range from the
trigger level up to the minimal
operating range are detected
by the TPS.
Objects in the range from the
trigger level down to ground
are not detected by the TPS.
S
door
S
gap
© CEDES | V 1.6
English
> 0.1 m
> 0.2 m
> 0.1 m

Advertisement