82
en | Appendices
8.3.3

Areas with blocking time

Disarming of an area can be optionally influenced by means of a blocking time. An external
alarm from the area cancels the blocking time, i.e. disarming is possible.
1.
2.
3.
8.3.4

Access Levels

The standard distinguishes between four access levels (AE):
Level 2A is a subset of level 2B.
Selecting the access level
AE 1 Access for everyone, no authorization/code required
AE 2A Access for users, user passcode required
AE 2B Access for users, user passcode required
AE 3 Access for installers via control center
1.
2.
3.
AE 3 Access for installers via RPS for MAP
1.
2.
AE 4 Access for manufacturers via RPS for MAP
1.
2.
3.
4.
5.
2019-09 | 25 | F.01U.168.332
Under Area (area manager), select the desired Time Model.
Please note: Disarming is possible within a defined time interval.
A Time Model is made up of Day Models and can be adapted or created in the user
manager if necessary.
A blocking time can be changed by the user at the control center up to seven days in
advance if the user has the corresponding permissions. User Manager > Permission Sets
> Operations Category > May Edit Blocking Time
AE 1 Access for everyone, no authorization/code required
AE 2A Access for users, user passcode required
AE 2B Access for users, user passcode required
AE 3 Access for installers via control center or via RPS for MAP
AE 4 Access for manufacturers via RPS for MAP
Open control panel enclosure.
The internal warning device is activated for 3 sec.
Switch to installer mode (refer to Installer button, page 66).
Enter installer passcode.
Open control panel enclosure.
Internal warning device is activated for 3 sec.
or
authorize from RPS with an AE 2 user with corresponding permissions (control center:
main menu page 2 > RPS).
Establish a connection between the panel and RPS.
Authorize the manufacturer user with an AE 3 user with corresponding permissions
(control center: main menu page 1 > maintenance page 3 > manufacturer permission).
Open control panel enclosure.
The internal warning device is activated for 3 sec.
Switch to installer mode = AE 3 (Installer button, page 66).
Login with the passcode of the manufacturer at the installer control center (Manufacturer
authorization, page 59).
Establish a connection between the panel and RPS.
1
Installation manual
1
1
Bosch Security Systems B.V.
MAP 5000