INSTALLING AN OPTIONAL WALL SWITCH
see Figure 5.1
1.
Install a single-gang electrical workbox (not supplied) at the
desired location - no more than 26 feet as the cable runs.
2.
While keeping the black connector (A) inside the work box,
thread the black 4-wire cable through the workbox and bring
the red connector (B) to the location of the receiver.
3.
Connect the black connector (A) to the wall switch, the red
connector (C) to the receiver.
4.
Test for proper operation then screw the wall switchplate to
the workbox with the two screws provided and attach the
faceplate (included).
USING THE WALL SWITCH
see Figure 5.2
Note that, with the wall switch, you can turn the fireplace on and off and adjust the flames up
and down. The rear burner, however, can only be turned on/off with the remote control (model
applicable).
Turn fireplace ON: Press the ON/OFF button until a short beep confirms the start sequence
has begun then release the button.
Increase the flame height: Press and hold the UP button.
Decrease the flame height: Press and hold the DOWN button.
For fine adjustment tap the UP or DOWN button as necessary.
Turn fireplace OFF: Press the ON/OFF button.
Element4 Gas Fireplaces
APPENDIX THREE
61
B
A
Figure 5.1
UP
ON/OFF
DOWN
Figure 5.2