GENERAL NOTES
NOTICE
Wiring of valve and receiver must be completed before starting
ignition. Failure to do so could damage the electronics.
Batteries – Remote
• Low battery indicator on remotes.
Batteries – Receiver
• Low battery indication: frequent beeps for 3 seconds when motor
turns.
• Instead of batteries, the included AC adapter should be used for
improved reliability and customer satisfaction.
WARNING
• Old or dead batteries should be removed immediately. If left in the
unit the batteries can overheat, leak, and/or explode.
• Do NOT expose batteries (including during storage) to direct
sunlight, excessive heat, fire, moisture, or severe impact. Each of
these conditions can cause the batteries to overheat, leak, and/or
explode.
• New and old batteries and different brands of batteries should
not be used together. Mixing of various batteries can cause the
batteries to overheat, leak, and/or explode.
Software Version
Press
and
buttons simultaneously. Software version is displayed.
Remote Model Number
Press
and
buttons simultaneously. Remote model number is
displayed.
Deactivate Functions
1. Install batteries. All icons are displayed and flashing.
2. While the icons are flashing, press the relevant function button and
hold for 10 sec.
3. The function icon will flash until deactivation is complete.
Deactivation is complete when the function icon and two
horizontal bars are displayed.
NOTE:
If a deactivated button is pressed, there is no function, and
two horizontal bars are displayed.
NOTE:
Deactivation remains in effect after change of batteries.
Activate Functions
1. Install batteries. All icons are displayed and flashing.
2. To activate a function, press the relevant button and hold for
10 sec.
3. The function icon will continue to flash until activation is complete.
Activation is complete when the function icon is displayed.
Element4 Gas Fireplaces
OPERATING the FIREPLACE
The following Functions can be Deactivated/Activated
• CHILD PROOF (To activate press
displayed and the remote is rendered inoperable (except for
off function).
• PROGRAM MODE
• THERMOSTATIC MODE (also deactivates Program Mode)
• ECO MODE
• LIGHT/DIMMER OPERATION
• CIRCULATING FAN OPERATION
• AUXILIARY FEATURE
• COUNTDOWN TIMER
Automatic Turndown.
1. In Manual/Temperature/Timer modes, the valve will turn to pilot
flame if there is no change in flame height for a six hour period.
In Temperature or Timer mode, if the ambient room temperature
changes, the flame height will adjust automatically to maintain set
temperature and the fire will continue to function normally. The
valve will turn to pilot flame if the set temperature and the ambient
room temperature remain the same over a six hour period.
2. The valve turns to pilot flame if the temperature in the receiver is
higher than 140°F/60°C. The burners comes back on only when the
temperature is below 140°F/60°C.
Automatic Shut Off.
1. With low battery power in the receiver, the system shuts off
the fire completely. This does not happen if the power supply is
interrupted.
2. The system shuts off the fire completely if there is no change in
flame height for 5 days.
3. The system shuts off the fire if the main burner does not
completely ignite approximately 20 seconds after ignition or after
pushing the
button.
48
and
buttons simultaneously.