FUNCTION
I.
Magnet unit drops
while motor turns.
Receiver makes 3
beeps.
No
J.
Flames become
thin, blue, wispy
then go out.
No
K.
Flames are very
yellow with dark,
sooty tips.
No
L.
Flames are very
busy and blowing in
an abnormal direc-
tion.
No
M.
Flames are stable
but too small and
blue.
No
NORMAL
OPERATION
Element4 Gas Fireplaces
APPENDIX TWO
POSSIBLE CAUSE
Receiver batteries low.
Yes
Ensure magnet unit is operating
normally.
Exhaust is contaminating the fresh air.
Flow of fresh air and/or exhaust is
Yes
blocked.
LP gas being used with NG orifice(s).
The air shutter is closed when using
LP gas.
Flow of fresh air and/or exhaust is
Yes
blocked.
Air leak in the firebox.
Yes
Too much primary air.
Yes
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
Test the receiver output to the magnet unit.
Inspect venting for damage and/or incorrect
installation.
Ensure that vent configuration is within the
vent chart requirements.
Check termination for blockage and/or
appropriate type.
Ensure the gas type is correct for the
installed orifices.
When using LP gas the air shutter must be fully
open. See conversion instructions.
Ensure that vent configuration is within the
vent chart requirements.
Check termination for blockage and/or
appropriate type.
Check unit for leaks at glass corners or at
gaskets.
Check unit for positive relief door seal.
Check venting for complete integrity.
Reduce the primary air opening until flames have blue
base and yellow upper two-thirds.
60