FUNCTION
No
No
B.
No
Magnet unit is
energized thus pro-
ducing an obvious
latching sound.
Yes
C.
Spark will occur
each second.
Yes
(continued)
Element4 Gas Fireplaces
APPENDIX TWO
No beep
3 short beeps
1 long beep
Ignition components not
No
operating properly.
Ignition sequence stops after one spark
No
Ignition sequence stops, no pilot flame.
No reaction to remote command.
No
Ignition sequence stops, no pilot flame.
No
Remote command is possible.
POSSIBLE CAUSE
Impulse magnet not
operating properly.
Receiver batteries low.
8-wire cable is off or
not operating
properly.
SW-cable
disconnected.
Motor not operating
properly.
Micro switch not
operating properly.
ON/OFF switch is in
the OFF (O) position.
2nd thermocouple
not connected
Check connection between ignition cable and ignition
electrode.
Check ignition electrode spark gap.
Check ignition electrode.
Check ignition cable for damage.
Increase distance between ignition cable and all metal
parts.
57
REMEDY
Replace gas valve.
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
Confirm proper operation of the 8-wire
cable.
Confirm proper connection/operation of
the SW-cable.
Replace gas valve.
Replace gas valve.
If equipped, set switch to ON ( | ) position.
Confirm integrity of 2nd thermocouple and
connection.
Remove ground bolt (T20 Torx, above) and
clean ground lug.
Reset system, see the installation manual or
the label on the receiver.
Do not coil the ignition cable.
Shorten the ignition cable, if possible.
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.