Turn the power switch off.
Remove the brewer's rear cover.
Turn the power switch on.
Hold the SET button for 5 seconds, until the display reads SET.
Next, the display will show the software version
Press SET. The first parameter number will be displayed briefly,
followed by the current setting.
Example: 1.1 = Batch 1 pulse ON time, 20 seconds
Use the UP and DOWN buttons to adjust the setting.
Press SET again. The next parameter will be displayed briefly,
followed by the current setting.
Example: 1.2 = Batch 1 brew only at set temperature, 1
Use the UP and DOWN buttons to adjust the setting.
Continue this way until all parameters are programmed.
See the chart below for an explanation of each parameter.
Important! To save your changes and return to operating mode,
you must hold SET for 5 seconds until the display reads STo.
Parameter
Name
0.0
Software Version
1.1
Pulse ON time
(A higher setting
lowers the total brew
time & vice versa.)
1.2
Brew at Set
Temperature
1.3
Prewet
(5 second spray-over
followed by 30 second
delay)
1.4
Drip Delay (Min:Sec)
1.5
Brew Time
3.0
Water Temp. (°F)
4.0
Reload Default
Settings

Error Codes

Error codes are indicated by the flashing of the "ready" light and an error code number displayed on the control
board. To reset error codes, turn the power switch off and on.
050 - Shorted Temperature Probe
051 - Open Temperature Probe
101 - Fill Error (Tank did not fill within 2 minutes, 20 seconds.

Programming

Example:
Range
Increment
5 – 30 sec.
1
0 - 1
0 - 1
10 sec – 3 min
10 sec.
185°F - 208°F
1°F
0 - 1
7
Display
SET
0.6
1.1
20
1.2
1
STo
Default Setting
Comment
Displays current version.
20 seconds
The amount of time that
water sprays out of each
30 second cycle.
(20 sec. ON, 10 sec. OFF)
1
0=Will brew at any
temperature.
1=Will brew only at set
temperature.
0
0=Prewet disabled.
1=Prewet enabled
50 seconds
Time between the end of
(Displays as
the brew cycle and the
0.5)
brew light stops flashing.
3 min, 10 sec
Display only. Not
(Displayed as
adjustable. This is a
3.1)
calculated value based on
programmed settings.
205°F
0
Changes all settings to
default factory settings.
0 = Do not reload defaults
1 = Reload all defaults
CONTROL BOARD
The display shows the
actual water temperature
when not in Programming
mode.