Safety Data Sheet Océ 9300 Printer - Oce 9300 User Manual

Table of Contents

Advertisement

Safety data sheet Océ 9300 printer
The contents of this safety data sheet is subject to the disclaimer on page 111
of this manual.
112
Océ 9300 User Manual
PRODUCT SAFETY DATA SHEET
Model
Description
Max. process speed
Dimensions
Width
Depth
Height
Weight
Voltage
Frequency
Current-rated
Current-max
Power consumption
Power consumption, stand by
Mains connection
Safety class
Protection class
Sound pressure level
(at bystander position)
Sound power level
Radio interference
Radiation
Heat emission
Ozone emission
Room volume
Room ventilation
Use simulation at random
operation
Consumables
Additional safety information
Listed according to standard UL 1950 and CAN/CSA-C22.2 No.950
Copyright © 1999 Océ-Technologies B.V., Venlo, NL
Océ 9300
Electrostatic printer, instant printing, console model, plain paper, organic photoconductive
drum, powder toner
3 m/min
1 roll
2 roll
1352 mm
1352 mm
918 mm
918 mm
1251 mm
1251 mm
149 kg
159 kg
115 V
60 Hz
15 A
20 A
1500 W at continuous operation
46 W
Cable with plug
I
(IEC 536) Protective earth connection
IP 20
(IEC 529)
Stand by
In operation
0 dB(A)
main body 51 dB(A)
impulse ∆ L
0 dB(A)
main body 61 dB(A)
Complies with FCC rules and regulations, part 15 class A
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Standby 46 W; at continuous operation 1500 W
0,02 mg/min at continuous operation
3
Recommendation: min. 25 m
3
Recommendation: min. 12,5 m
/h (natural ventilation)
With a room volume and ventilation as recommended and a daily volume of 100 m (much
more than average) the use simulation at random operation gives the following ozone
concentrations:
- Time weighted average
- Peak
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone
Odour Perception Limit for ozone
Océ OPC Drum (Océ Safety Data Sheet E-218)
Océ B4 Toner (Océ Safety Data Sheet E-196)
Océ D4 Developer (Océ Safety Data Sheet E-197)
Océ Copying Materials.
This apparatus is suitable for processing recycling paper. Ask Océ for suitable recycling
paper.
The ozone ?lter does not have to be replaced to keep the ozone concentration in the
3
workplace below 0,04 mg/m
(i.e. the life of the ?lter equals that of the apparatus).
LISTED 927F
INFORMATION
TECHNOLOGY
EQUIPMENT
E 69871
Number
E-708-a-US
Date
August 1999
= 2 dB(A)
i
3
0,002 mg/m
(0,001 ppm)
3
0,008 mg/m
(0,004 ppm)
3
0,2 mg/m
(0,1 ppm)
3
0,04 mg/m
(0,02 ppm)

Advertisement