Left and Right Cylinder (LC and RC)
1. Disconnect the Left Up hose from the machine's hydraulic valve and
install a supplied tee into the valve.
2. Re-connect the Left Up hose to the installed tee fitting.
3. Attach the supplied hose (P/N 214-1000-309) from the tee to the Left
Cylinder (LC) port on the Autoboom valve.
4. Repeat steps 1 through 3 to connect the Right Up and Right Cylinder
(RC) ports.