Fault Log
Entry
LHx Arc
Latched Helix Arc Fault
LHx Arc2
Latched Helix Arc Fault on 2nd
TWT in dual tube units
Lo Drv A
Input Drive Low Alarm:
Software Power Limit function,
Constant Power
Lowline
Low-line Fault
LowPwr A
Customer settable Low
Forward RF Power Alarm
LowPwr F
Customer Settable Low
Forward RF Power Fault
MNC-0400-048
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.
Table 1TWTA Fault Log Troubleshooting
Description
11 of 14
Operation, TWTA ODU Amplifier
Possible Cause of
Fault
The maximum
Check for properly
number of
connected
Momentary Helix
waveguide, and a
Arc faults has been
properly terminated
detected.
load. If TWT has
been in stroage, run
unit in Standby for
several hours, then
try again.
The maximum
Check for properly
number of
connected
Momentary Helix
waveguide, and a
Arc faults has been
properly terminated
detected.
load. If TWT has
been instorage, run
unit in Standby for
several hours, then
try again.
Input Drive level is
1. Increase input
too low.
drive power. 2.
Change output RF
power limit. 3.
Disable feature.
Input A/C power is
Check A/C power
too low, or power
input for proper
supply is failing.
levels.
The output RF
1. Increase input
power is below the
drive power. 2.
set minimum level.
Change output RF
power minimum
level. 3. Disable
feature.
The output RF
1. Increase input
power is below the
drive power. 2.
set minimum level.
Change output RF
power minimum
level. 3. Disable
feature.
Action Needed to
Clear Fault
Revision B