Calibration system is
wrong
Medium viscosity is too
high
Medium cavitations
Check valve leakage
Suction pipe leakage
Flow
becomes
Filter is blocked
lower
gradually
Medium is changed
Blowhole of the offering
tank is blocked
Suction piping leakage
Flow is
Medium cavitations
unstable
Check valve is blocked
Evaluate and correct it
Improve temperature of product or
lower the viscosity. Increase the
size of pump and pipeline.
Increase the pressure of suction,
and shorten the suction pipe.
Clean or change the valve
Find the leakage position and
solute the problem.
Disassemble the filter; clean or
change it.
Check the viscosity and other
parameters
Open the blowhole
Find the leakage position and
solute the problem.
Increase the pressure of suction and
shorten the suction pipe.
Clean or change it
- 14 -