Planmeca ProMax 2D User Manual
Hide thumbs Also See for ProMax 2D:

Advertisement

Planmeca ProMax
®
2D & 3D s & 3D Classic
user's manual
2D imaging

Advertisement

Table of Contents
loading

Summary of Contents for Planmeca ProMax 2D

  • Page 1 Planmeca ProMax ® 2D & 3D s & 3D Classic user's manual 2D imaging...
  • Page 3: Table Of Contents

    Patient positioning ........................ 56 11.4 Taking an exposure ......................59 SETTINGS ........................60 12.1 User settings ........................61 12.2 Program settings ........................68 12.3 About tab ..........................71 User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 4 IEC 60364 - equipment is used according to the operating instructions. Planmeca pursues a policy of continual product development. Although every effort is made to produce up-to-date product documentation this publication should not be regarded as an infallible guide to current specifications. We reserve the right to make changes without prior notice.
  • Page 5: Introduction

    The X-ray unit uses panoramic techniques to produce two-dimensional (2D) X-ray images for the examination of dentomaxillofacial anatomy. You need a PC with the Planmeca Romexis program in order to save, view and modify the images. Make sure that you are fully acquainted with the appropriate radiation protection measures and these instructions before you use the X-ray unit.
  • Page 6: Associated Documentation

    User’s Manual, Original English publication: 10014593 • Installation Manual, Original English publication: 10014600 NOTE The latest versions of the User’s Manuals are available on Planmeca’s website (Material bank > Manuals > Imaging). Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 7: Symbols On Product Labels

    Type B applied part (Standard IEC 60601-1) Separate collection for electrical and electronic equipment (Directive 2002/96/EC WEEE) Alternating current (Standard IEC 60417) Electrostatic sensitive device (Standard IEC 60417) User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 8: Safety Precautions

    Do not use the X-ray unit in an oxygen rich environ- ment or in the presence of flammable anesthetics. CAUTION Never use a defective or damaged X-ray system. Contact your service technician for help. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 9 FOR US & CANADIAN USERS: LASER RADIATION - The patient positioning lights are class II laser products (21 DO NOT STARE INTO BEAM CFR § 1040.10). CLASS II 635nm LASER PRODUCT User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 10 Contact your service technician if you notice a decrease in image quality. NOTE Contact your service technician if you have taken an exposure but the image does not appear in the Planmeca Romexis program. The last ten images can be manually imported into Romexis. NOTE Never place or hang any objects on any part of the X-ray unit.
  • Page 11: Switching X-Ray Unit On

    The on / off switch is located on the underside of the stationary column top. NOTE To prolong the lifetime of the X-ray unit, always switch the X-ray unit off when it is not in active use. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 12: Main Parts

    6 MAIN PARTS 6 MAIN PARTS 6.1 General view of 2D X-ray system Ethernet X-ray unit Planmeca Romexis program Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 13: General View Of 3D X-Ray System

    6 MAIN PARTS 6.2 General view of 3D X-ray system Ethernet X-ray unit 3D reconstruction PC Planmeca Romexis program User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 14: General View Of X-Ray Unit

    6.3 General view of X-ray unit Cephalostat (optional) C-arm Patient support Patient support table Patient handles Patient positioning Dimax sensor controls Touch screen 3D sensor on C-arm Telescopic column Stationary column Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 15: Sensors

    Dimax sensor 3D sensor for Planmeca ProMax 3D s 3D sensor for Planmeca ProMax 3D Classic ProFace sensor for Planmeca ProMax 3D s and Planmeca ProMax 3D Classic User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 16: Patient Supports

    6 MAIN PARTS 6.5 Patient supports Bite piece Chin rest Adapter Chin cup Chin support Temple supports Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 17: Exposure Switch

    A help message will appear on the touch screen. Guide the patient away from the X-ray unit. Then release the emergency stop button. The X-ray unit will automatically restart. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 18: Touch Screen

    • Right button: To view two program bars on top of each other, select the right button at the bottom of the main screen. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 19 The selected option is highlighted. To deselect an option, touch the button or field again (or select an other option if available). NOTE Do not use sharp objects to operate the touch screen. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 20 You can turn demo mode on if you wish to practice or demonstrate the functions of the X-ray unit without radiation (Settings > User > 1300 Operational settings > 1310 Use Mode > 1311 Set Demo Mode). Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 21: Patient Positioning Controls

    Make sure that there is no object under the telescopic column when you press the down button. If something is in danger of becoming trapped, release the button immediately to stop the movement. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 22 Open / close temple supports Press the temple support button to open the temple supports in 2D imaging. The temple supports can be closed by pressing the temple support button again. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 23: Programs

    The X-ray unit uses SCARA (Selectively Compliant Articulated Robot Arm) technology for arm movements. Planmeca ProMax 2D S3 and Planmeca ProMax 3D units have three joints (S3 = SCARA 3) and allow limitless imaging possibilities. Planmeca ProMax 2D S2 units have two joints (S2 = SCARA 2) and offer a more limited selection of exposure programs.
  • Page 24: Temporomandibular Joint (Tmj) Programs

    17°. Posteroanterior exposures are taken perpendicular to the long axis of the condyle (90° - 17° = 73°). The condyle angle is shown as default angle. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 25 2. Posteroanterior exposures are taken perpendicular to the long axis of the condyle (90° - 17° = 73°). The condyle angle is shown as default angle. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 26: Sinus Programs

    7 PROGRAMS 7.3 Sinus programs Posteroanterior Posteroanterior sinus exposure. Posteroanterior linear Posteroanterior linear sinus exposure. Lateral Lateral exposure of the left or right sinus area. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 27: Preparations For Exposure

    - contact your service technician for help. If you have any reason to believe that the sensor might be faulty, take a test exposure before taking a patient exposure. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 28 This will secure the sensor in position. Push in the C-arm electrical connector button on the other side. This will make the electrical connection between the sensor and C-arm. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 29 Push in the C-arm electrical connector. This will disconnect the electrical connection between the sensor and C-arm. Turn the locking knob 180 degrees. This will release the locking mechanism. Carefully pull the sensor out. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 30: Preparing Planmeca Romexis

    NOTE High contrast objects, such as gold teeth or amalgam, may cause artefacts in the image. Place a protective lead apron over the patient’s back if required. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 31: Panoramic Exposure

    NOTE We recommend that you use the chin support when taking bitewing exposures. Chin support User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 32: Selecting Exposure Settings

    NOTE Selecting child patient (XS) will automatically reduce the exposure area and patient dose. NOTE The exposure values will automatically change according to the selected patient size. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 33 Select the green check mark button. Select the forward button or the fast forward button if you want to skip the next screen. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 34 12.2.1 “Programs (2100)” on page 68. 9.2.4 Selecting program type Select the program type from the drop-down menu at the top. Refer to section 7.1 “Panoramic programs” on page 19 for details. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 35 C. U-shaped NOTE The jaw size will automatically change according to the selected patient size (XS = 1, S & M & L = 2, XL = 3). User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 36: Patient Positioning

    Selecting the right button will move the C-arm to the back, away from the patient positioning area. This full view position allows you to monitor and adjust the patient’s position freely from all directions. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 37 1330 Patient positioning). This might be necessary if there is no space for the C-arm to move back. NOTE Planmeca ProMax 2D S2 units offer only one patient entry position. This entry position is the closed patient entry position where the C-arm is positioned around the temple supports.
  • Page 38 To switch them back on, do one of the following: • Press the thumb wheel on the underside of the Thumb wheel patient support table. • Press any of the positioning controls (button or joystick). Positioning controls Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 39 Frankfort plane light. To do this, adjust the tilt of the patient’s head by raising or lowering the X-ray unit with the height adjusting buttons. The patient’s back and neck should be straight. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 40 Frankfort plane light are still correctly positioned. Reposition them if necessary. Thumb wheel NOTE Make sure that you have selected the correct patient and exposure mode in the Planmeca Romexis program. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 41: Selecting Dynamic Exposure Control (Dec)

    The setting can be adjusted between 20% (lower exposure values -> brighter image) and 200% (higher exposure values -> darker image). The recommended setting is 100% (default setting). User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 42: Taking An Exposure

    The image is shown on the computer screen. • Note that you must accept the image in the Planmeca Romexis program. Refer to the Romexis User’s Manual. Guide the patient away from the X-ray unit. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 43: Taking An Exposure With Autofocus

    9 PANORAMIC EXPOSURE 9.6 Taking an exposure with Autofocus NOTE Autofocus is an optional feature for Planmeca ProMax 2D S3 units. It is available for standard, interproximal and orthogonal panoramic programs. NOTE To turn Autofocus on, select Settings > Program > 2200 Program Features >...
  • Page 44 The image is shown on the computer screen. • Note that you must accept the image in the Planmeca Romexis program. Refer to the Romexis User’s Manual. Guide the patient away from the X-ray unit. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 45: Temporomandibular Joint (Tmj) Exposure

    Adapter 10.2 Selecting exposure settings Refer to section 6.8 “Touch screen” on page 14 for general information on how to make or cancel selections on the touch screen. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 46 Extra large adult (XL) Factory presets for posteroanterior TMJ exposures PATIENT SIZE kV VALUE mA VALUE Child (XS) Small adult (S) Medium-sized adult (M) Large adult (L) Extra large adult (XL) Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 47 Use the second button on the left of the screen to select the jaw side(s) you wish to expose. Select jaw side (right / left / both sides for double exposures) User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 48: Patient Positioning

    10 TEMPOROMANDIBULAR JOINT (TMJ) EXPOSURE 10.2.6 Selecting imaging angle (Planmeca ProMax 2D S3 & Planmeca ProMax 3D units) Use the arrow buttons in the middle of the screen to select the imaging angle for this exposure. Select imaging angle NOTE To change the default angle (17 degrees), select Settings >...
  • Page 49 To switch them back on, do one of the following: • Press the thumb wheel on the underside of the patient support table. Positioning • Press any of the positioning controls (button or controls joystick). User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 50 10 TEMPOROMANDIBULAR JOINT (TMJ) EXPOSURE 10.3.3 Adjusting patient’s head position (Planmeca ProMax 2D S2 units) The positioning lights and the illustrations on the touch screen help you to position the patient’s head correctly. NOTE The illustrations are for guidelines only.
  • Page 51 2). To do this, select Settings > Program > 2200 Program Features > TMJ 2/2 Shift and adjust the setting with the minus or plus sign (e.g. 10 mm). User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 52 10 TEMPOROMANDIBULAR JOINT (TMJ) EXPOSURE 10.3.4 Adjusting patient’s head position (Planmeca ProMax 2D S3 & Planmeca ProMax 3D units) The positioning lights and the illustrations on the touch screen help you to position the patient’s head correctly. NOTE The illustrations are for guidelines only.
  • Page 53 2). To do this, select Settings > Program > 2200 Program Features > TMJ 2/2 Shift and adjust the setting with the minus or plus sign (e.g. 10 mm). User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 54: Taking An Exposure In Double Tmj Programs

    NOTE If needed, you can stop the imaging process by touching the red cross button after you have taken the first exposure. Red cross button Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 55 The image is shown on the computer screen. • Note that you must accept the image in the Planmeca Romexis program. Refer to the Romexis User’s Manual. Guide the patient away from the X-ray unit. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 56: Taking An Exposure In Three Angle Tmj Programs

    The image is shown on the computer screen. • Note that you must accept the image in the Planmeca Romexis program. Refer to the Romexis User’s Manual. Guide the patient away from the X-ray unit. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 57: Sinus Exposure

    Refer to section 6.8 “Touch screen” on page 14 for general information on how to make or cancel selections on the touch screen. 11.2.1 Selecting program Select the sinus program. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 58 Extra large adult (XL) You can adjust the preset exposure values (kV and mA) as described in section 9.2.3 “Adjusting exposure values for current exposure” on page 29. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 59 11.2.5 Selecting jaw side (lateral exposures) Use the second button on the left of the screen to select the jaw side you wish to expose. Select jaw side (right / left) User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 60: Patient Positioning

    To switch them back on, do one of the following: Thumb wheel • Press the thumb wheel on the underside of the patient support table. • Press any of the positioning controls (button or Positioning joystick). controls Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 61 Frankfort plane light. To do this, adjust the tilt of the patient’s head by raising or lowering the X-ray unit with the height adjusting buttons. The patient’s back and neck should be straight. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 62 The Frankfort plane light is located inside the column. light The light’s position can be adjusted if needed. This is done by rotating the thumb wheel below the light slot. Thumb wheel Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 63: Taking An Exposure

    The image is shown on the computer screen. • Note that you must accept the image in the Planmeca Romexis program. Refer to the Romexis User’s Manual. Guide the patient away from the X-ray unit. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 64: Settings

    Settings that can be entered by service personnel only (password required): • Technical To return to the main view, select the settings icon at the top left corner. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 65: User Settings

    Select User > 1200 Time and Date > 1210 Set System Time and Time / Date Display Format > Time Display Format. Select the display format you wish to use. Select the green check mark button. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 66 NOTE The time is set to the local time at the factory. Change the time setting to show the correct time before you start using the X-ray unit. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 67 Select the mode you wish to use. In demo mode you can practice or demonstrate the functions of the X-ray unit without radiation and PC connection. Select the green check mark button. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 68 C-arm to move back. NOTE Planmeca ProMax 2D S2 units offer only one patient entry position. This entry position is the closed patient entry position where the C-arm is positioned around the temple supports.
  • Page 69 Select User > 1400 Network Settings. Select the network settings you wish to view. Select the green check mark button. NOTE Only a service technician or local administrator may change the network settings. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 70 Press and hold down the exposure button for the duration of the exposure. The C-arm will not move when you take a test exposure. Select the green check mark button. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 71 Select User > 1600 Clinic Management to view the network settings for the Planmeca Romexis Clinic Management module. NOTE Only a service technician or local administrator may change the settings. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 72: Program Settings

    Program > 2500 Reset to Factory Defaults. NOTE You can adjust the preset exposure values temporarily as described in section 9.2.3 “Adjusting exposure values for current exposure” on page 29. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 73 To manage program settings: Select Program > 2200 Program Features to manage program settings. For details on a specific setting, refer to the manual section that contains the corresponding function. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 74 Select the green check mark button. NOTE The function will restore the exposure values that have been preset at the factory (i.e. overrule your own settings in menu Programs (2100)). Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 75: About Tab

    The errors are shown in chronological order with the latest error message on top. • To view exposure statistics: Select About > 4200 Archive > Exposure Statistics to view statistical data about the X-ray unit. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 76: Help Messages

    The line voltage was too low during Exposure was interrupted. exposure. Contact your service technician for help. H152 The line voltage is too low. Exposure is not possible. Contact your service technician for help. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 77 Use the 3D Model programs for used for patient imaging. taking exposures of impressions or plaster casts only. H196 Remove all 3D / panoramic patient sup- ports before taking cephalometric images. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 78: Error Messages

    Guide the patient away from the X-ray unit. Then clear the message by touching the green check mark. Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 79: Cleaning

    X-ray unit must be checked and recalibrated by a qualified Planmeca service technician once a year or after every 10 000 exposures if this is sooner. User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 80: Disposal

    - plastic PUR, other plastics Motors Component boards Cables, Copper, transformers steel, transformer oil X-ray tube Packing Wood, cardboard, paper, polystyrene Sensor Return sensor to Planmeca. Other parts Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 81: Technical Specifications

    60 - 90 kV ±5% 3D Max: 60 - 96 kV ±5% • Pan / SmartPan 60 - 84 kV ±5% • Ceph 60 - 84 kV ±5% User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 82 High Speed: 6.4 - 9.9 s as indicated ±10% X-ray units with SW 3.0 or later: 6.4 - 9.9 s as indicated ±10% • Planmeca ProCeph 0.1 - 0.8 s as indicated ±10% Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 83 2D / 3D s / 3D Classic 119 kg (263 lb) • 3D Plus / 3D Mid 136 kg (300 lb) • 3D Max 134 kg (296 lb) User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 84 3D Mid: 8 x 146 mm (0.31 x 5.74 in.) 3D Max: 13 x 162 mm (0.51 x 6.38 in.) 3D Max MultiView: 25 x 162 mm (0.98 x 6.38 in.) Pan / ceph CCD: Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 85: Original Manufacturer

    • No green objects next to X-ray 18.2 Original manufacturer PLANMECA Oy, Asentajankatu 6, FIN-00880 Helsinki, FINLAND Phone: +358 20 7795 500, Fax: +358 20 7795 555, www.planmeca.com User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 86: Dimensions

    Scanning ceph or Planmeca ProCeph SCARA 3: 1145mm (45.1”) SCARA 3: 850mm (33.5”) SCARA 2: 1170mm (46.1”) 270mm (10.6”) 150mm SCARA 2: 698mm (27.5”) (5.9”) Scanning ceph or Planmeca ProCeph Planmeca ProMax 2D & 3D s & 3D Classic User’s Manual (2D)
  • Page 87: Minimum Operational Space Requirements

    Planmeca ProMax 2D S3 X-ray unit 2150 mm 1630 mm 1560 - 2385 mm with cephalostat 84.6 in. 64.2 in. 61.4 - 93.9 in. Planmeca ProMax 3D X-ray unit with cephalostat User’s Manual (2D) Planmeca ProMax 2D & 3D s & 3D Classic...
  • Page 90 Planmeca Oy | Asentajankatu 6 | 00880 Helsinki | Finland tel. +358 20 7795 500 | fax +358 20 7795 555 | sales@planmeca.com | www.planmeca.com...

This manual is also suitable for:

Promax 3d sPromax 3d classic

Table of Contents