9.1.2 Inverter warning

Warning code
For CPSPV7000ETL – CPSPV12000ETL :
Problem with fan 1 or fan 2.
Warning100
For CPSPV7000ETL / CPSPV20000ETL:
Problem with fan 1, fan 2, fan 3 or fan 4.
Warning104
Firmware version does not match.

9.1.3 Inverter fault

Error code
Communication board has not received
data from control board for 10 seconds.
Error: 101
Electromagnetic
communication problem.
Error: 117
Relay fault.
GFCI module fault.
Error: 119
(Ground Fault Circuit Interrupter)
Error: 121
Communication fault.
Error: 122
Bus voltage fault.
PV ISO fault.
Error: 125
(Low isolation)
Error: 126
High GFCI
Error: 127
High DCI
Error: 128
High PV voltage
Error: 129
Grid voltage fault.
Error: 130
Grid frequency fault.
User Manual
Meanings
Meanings
Interference
cause
53 / 61
Suggestion
1. Check whether there is anything above fans,
clear them;
2. Turn off dc switch, rotate fan blade with
screwdriver, and then restart inverter.
3. If Warning still exist, Contact CyberPower.
1. Restart the inverter.
2. If Warning still exist, Contact CyberPower.
Suggestion
1. Restart inverter by cutting off DC supply, and
Error message will disappear.
2. If the error 101 is often displayed, the
environment Electromagnetic Interference is too
strong. Contact CyberPower.
Restart inverter, if problem still exist, Contact
CyberPower.
Restart inverter, if problem still exist, Contact
CyberPower.
Restart inverter, if problem still exist, Contact
CyberPower.
Restart inverter, if problem still exist, Contact
CyberPower.
1. Refer the suggestion of error "PV Isolation Low".
2. If problem still exist, Contact CyberPower.
Restart inverter, if problem still exist, Contact
CyberPower.
1. Refer the suggestion of error "Output High DCI".
2. If problem still exist, Contact CyberPower.
1. Refer the suggestion of error "PV Voltage High".
2. If problem still exist, Contact CyberPower.
1. Refer the suggestion of error "AC V Outrange".
2. If problem still exist, Contact CyberPower.
1. Refer the suggestion of error "AC F Outrange".
2. If problem still exist, Contact CyberPower.
CPS Mini Central series