(ill. 11)
Open the clamp (K) and hold. Place the contact in the
appropriate cross section range.
Turn the crimp lugs upwards. Release the clamp (K). The
contact is fixed.
(ill. 12)
Press the pliers gently together until the crimp lugs are
properly located within the crimping die.
(ill. 13)
Insert the stripped cable end until the insulation comes up
against the crimp insert. Completely close the crimping
pliers.
(ill. 14)
Visually check the crimp.
(ill. 15)
Insert the crimped-on contact into the insulator of the male
or female coupler until it clicks into place. Pull gently on
the lead to check that the metal part is correctly engaged.
(ill. 16)
Insert the appropriate end of the test pin into the male or
female coupler as far as it will go. If the contact is correctly
located, the white mark on the test pin must still be visible.
29