Safe Mode

When Safe Mode has been activated, the
OPEN, PEDAL, and, LOCK LEDs will pulse
yellow and suspension Position switches to
OPEN.

Safe Mode Toubleshooting

If three yellow LEDs are illuminated Safe Mode has been activated.
Settings cannot be adjusted in the SRAM AXS app when Safe Mode is activated.
Safe Mode cannot be exited until the triggering issue has been resolved.
Refer to the table below to troubleshoot and restore function.
The Flight Attendant system enters Safe
Mode when the battery level of the fork or
rear shock Control Module, or Pedal Sensor
has reached a low state, or if a battery is
missing from a component.
Install a fully charged battery to return to
Auto Mode.
CAUSE
CORRECT
Control Module
battery has reached
Press AXS button,
a low charge level.
check LED color. If
Rear Shock Module
flashing red, battery
battery has reached
has reached a
a low charge level.
low charge level.
Replace battery with
Pedal Sensor battery
fully charged battery.
has reached a low
charge level.
Confirm rear shock
SRAM battery is
installed. Install
Control Module has
SRAM battery.
lost communication
Rear Shock may be
with rear shock.
asleep (off). Move
bicycle to wake (on)
the rear shock.
Safe Mode (OPEN) may also be activated if
communication with the rear shock is lost
due to its sleep (off) cycle.
Wake the rear shock with movement to
restore communication.
VERIFY
PREVENT
Check battery levels
before each ride and
charge or replace
batteries as needed.
Wake components
and confirm Control
Module LED pulses
green, and Auto
Mode has been
Confirm SRAM
activated.
battery latch is
closed correctly.
Move bicycle to
wake rear shock
before using Flight
Attendant.
32