Chassis Configuration Screen - Cabletron Systems 6H133-37 User Manual

Microlan smartswitch 6000 interface modules
Table of Contents

Advertisement

Chapter 5: Local Management
5.7

CHASSIS CONFIGURATION SCREEN

The Chassis Configuration screen,
chassis date and time, IP address and Subnet Mask, the operational mode
of all modules installed in the chassis, and to view the chassis uptime.
Access the Chassis Configuration screen from the Chassis Menu screen
by using the arrow keys to highlight the CHASSIS CONFIGURATION
menu item and pressing ENTER. The Chassis Configuration screen,
Figure
5-9, displays.
Event Message Line
MAC Address:
Chassis IP Address:
Subnet Mask:
Operational Mode: [802.1D SWITCHING]
SAVE
The following briefly defines each Chassis Configuration screen field:
MAC Address (Read-Only)
Displays the physical address of the chassis.
Chassis IP Address (Modifiable)
This field enables the IP address to be set for the 6C105 chassis. If an IP
address is assigned to the 6C105 chassis all the interface modules
installed in the chassis can be managed via this IP address, eliminating the
need to assign an IP address to each interface module. To set the IP
address, refer to
5-18
6C105 LOCAL MANAGEMENT
Chassis Configuration
00-00-ID-00-00-00
0.0.0.0
255.255.0.0
Figure 5-9 Chassis Configuration Screen
Section
5.7.2.
Figure
5-9, enables the user to set the
Chassis Date:
Chassis Time:
Screen Refresh Time:
Screen Lockout Time:
Chassis Uptime XX D XX H XX M
EXIT
6H123-50 and 6H133-37 User's Guide
10/11/97
14:23:00
30 sec.
15 min.
RETURN
2276_98