Built-In Construction Details - DCS THE PROFESSIONAL LIBERTY COLLECTION BFGC-30 Series Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION
BUILT–IN CONSTRUCTION DETAILS
Standard layout for non-combustible enclosure:
35-1/2"
Max.
Layout for insulated jacket only - combustible enclosure:
NOTE: See page 9 for insulated jacket
part ordering information.
grill
exhaust
Bottom of
support ange
2"
22-3/4"
25-1/2"
28-1/2"
10-1/8"
20"
NOTE: See page 9 for ventilation notes.
34-7/8"
18-1/2"
11-1/8"
20"
35-1/2"
Max.
NOTE: See page 9 for ventilation notes.
10
12" (to combustible construction)
10-1/16"
3/4"
3"
22-3/4"
18-1/2"
4" x 4" opening
for gas supply line
28"
opening for access doors
(see page 9 for ordering information)
12" min.
23-3/4"
4" x 4" opening
for gas supply line
3-1/2"
28"
opening for access doors/drawers
(see page 9 for ordering information)
Fig. 03
WARNING!
If installing the grill
into a non-combustible
enclosure, all combustible
construction must still be
outside the 12 inch clear-
ance zone. If your island
is made of stucco over the
top of wooden studs, the
wood can not be inside the
12 inch clearance zone to
combustible, even though
the stucco is what is touch-
ing the grill area.