INSTALLATION
BUILT–IN CONSTRUCTION DETAILS
Standard layout for non-combustible enclosure:
Layout for insulated jacket only - combustible enclosure:
NOTE: See page 9 for insulated jacket
part ordering information.
grill
exhaust
Bottom of
support flange
2"
22-3/4"
25-1/2"
28-1/2"
10-1/8"
20"
35-1/2"
Max.
NOTE: See page 9
for ventilation notes.
34-7/8"
11-1/8"
20"
35-1/2"
Max.
12" (to combustible construction)
10-1/16"
3/4"
3"
22-3/4"
18-1/2"
4" x 4" opening
for gas supply line
28"
opening for access doors
(see page 9 for ordering information)
12" min.
23-3/4"
4" x 4" opening
for gas supply line
18-1/2"
3-1/2"
28"
opening for access doors/drawers
(see page 9 for ordering information)
Fig. 03
10
WARNING!
If installing the grill into a
non-combustible
enclosure, all combustible
construction must still be
outside the 12 inch
clearance zone. If your
island is made of stucco
over the top of wooden
studs, the wood can not be
inside the 12 inch
clearance zone to
combustible, even though
the stucco is what is
touching the grill area.