Built-in Construction Details

Standard layout for non-combustible cavity
IMPORTANT!
If installing the grill into a non-combustible enclosure, all combustible construction must still be
outside the 457mm clearance zone. If your island is made of stucco over the top of wooden studs,
the wood cannot be inside the 457mm clearance zone to combustible, even though the stucco is
what is touching the grill area.
CAVITY DIMENSIONS
A Maximum height of enclosure shell
B Depth of enclosure shell
C Minimum depth for hood swing
D Width of enclosure cavity
E Height of enclosure cavity
Standard layout for non-combustible enclosure:
f Depth to gas supply opening
G Height of opening for access doors/drawers
H Width of opening for access doors/drawers
64,5 cm 2 /10 "2 Min. ventilation
on the back side
Ventilation options
Option 1 – Perforations, uniformly distributed over the height of the enclosure
The total free area must be equal to at least 25% of the side wall.
z
Option 2 – Separate openings at high and low levels
64,5 cm 2 /10 "2 min
The total free area at a high level must equal at least 20,000mm
ventilation
z
the cylinder compartment.
left
The total free area at a low level must equal at least 20,000mm
z
must sit within 15mm of the base of the cylinder compartment. The total free area must also sit
within 125mm of the base of the cylinder compartment.
25,72 cm/
10 1/8 "
The openings cannot be obstructed by the cylinder(s).
z
INSTALLATION
G
48" Models = 116,2 cm/45 3/4 "
36" Models = 87,6 cm/34 1/2"
46.36 cm/
18 1/2 "
D
C
F
E
H
FIG. 05
NOTE: If using a backguard
apron or rear wall, locate
electrical service on the
right hand side for rotisserie
motor connection
9,5cm / 3 3/4" Min. for Lid
57,79 cm/22 3/4 "
10,16 x 10,16cm
2
(4 x 4 ") opening
for gas supply
and a minimum of 25% of this area
2
line
Note: 102 x 102mm opening
for gas supply line
B
A
Note: the cut-out of each
corner should be a 90°angle
in order for the access doors/
drawers to fit properly.
BE1-48RCI
mm
902
578
95
1162
257
470
508
WARNING!
1168
If installing the grill into
a non-combustible
enclosure, all
combustible
construction must still
be outside the 18 inch
clearance zone. If your
and sit within 125mm of the top of
island is made of stucco
over the top of wooden
studs, the wood can not
be inside the 18 inch
clearance zone to
combustible, even
though the stucco is
BE1-36RCI
mm
902
578
95
876
257
470
508
864
15