Safety Instruction - Growatt 10000TL3-S Installation & Operation Manual

Hide thumbs Also See for 10000TL3-S:
Table of Contents

Advertisement

4
Unpacking
Before opening the packing box of UE series inverter, please note that whether there
are any visible external damages.
Once open the packing box, please check the delivery for completeness and for any
visible external damages of the inverter. If there are anything damaged or missing,
please contact your dealer. Complete delivery should contain as follows.
A
F
D
E
C
Number
Item
A
1
B
1
3
C
D
4
E
1
F
4
G
5/1
H
1
I *
2/3
--
1
* 3000-11000TL3-S & 12000TL3-S 2 Pairs
* 12000TL3-S & 15000TL3-S 3 Pairs
Though the packaging box of TL3-S is durable, please treat the
Information
packing box gently and avoid dispose the packing box.
11
B
G
H
Description
Inverter
Quick installation guide
Cable gland for AC connection
M4 cross recessed countersunk head screws
Rs485 terminals
Expansion bolt
Cord End Terminal/AC connector
RJ 45 PLUG Only for Australia
(
)
PV connectors
User manual (not show in the picture)

5.1 Safety instruction

I
Danger to life due to fire or explosion
Despite careful construction, electrical devices can cause fires.
Do not install the inverter on easily flammable materials and where
flammable materials are stored.
Risk of burns due to hot enclosure parts
Mount the inverter in such a way that it cannot be touched
inadvertently.
Possible damage to health as a result of the effects of radiation!
In special cases, there may still be interference for the specified application
area despite maintaining standardized emission limit values (e.g. when
sensitive equipment is located at the setup location or when the setup
location is near radio or television receivers).In this case, the operator is
obliged to take proper action to rectify the situation.
Never install the inverter near the sensitive equipment(e.g. Radios,
telephone, television, etc)
Do not stay closer than 20 cm to the inverter for any length of time unless it
is absolutely necessary.
We assumes no responsibility for compliance to EMC regulations for the
complete system.
All electrical installations shall be done in accordance with the local and
national electrical codes. Do not remove the casing. Inverter contains no
user serviceable parts. Refer servicing to qualified service personnel. All
wiring and electrical installation should be conducted by a qualified
service personnel.
Carefully remove the unit from its packaging and inspect for external
damage. If you find any imperfections, please contact your local dealer.
Be sure that the inverters connect to the ground in order to protect
property and personal safety.
The inverter must only be operated with PV generator. Do not connect
any other source to it.
Both AC and DC voltage sources are terminated inside the PV Inverter.
Please disconnect these circuits before servicing.
This unit is designed to feed power to the public power grid (utility) only.
Do not connect this unit to an AC source or generator. Connecting
Inverter to external devices could result in serious damage to your
equipment.
5
Installation
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents