Display Interface; Power On Display - Growatt 10000TL3-S Installation & Operation Manual

Hide thumbs Also See for 10000TL3-S:
Table of Contents

Advertisement

6.3.3 Display interface

Overall display interface introduction
Growatt
Setting
PV Inverter
SerNo:
PR34200090
Once
Model:
PVBC00F161
Power info
FW Version:
Once
DH 1.0–DH 0.0
Input Info
Once
Connect in: s
Output Info
Once
Connect OK
Set Info
AC VA/Watt:
Once
VA W
Inverter info
Etoday:
50 .2 Kwh
Once
Eall:
2000 Kwh
AC Error Record
1. Once:
2. Double:Enter
3.Three: Enter the setting
4.Four: Back to cycle display interface
Fig6.3 Overall display interface
31
Double
Double
Set Com Address
Set Com Address
Input Word:123
003
000
Once
Double
Set Language
Set Language
Input Word:123
123
Once
Double
AC V Control :
AC V Control :
Disable/Enable
Once
Double
Set Date/Time
Date:2012/04/05
Time:14:20:38
Double
Once
Etoday:
Eall:
50 .2 Kwh
2000 Kwh
Double
Once
PV1 Volt:
V
PV2 Volt: V
Power:
W
Power:
W
Double
Once
Once
AC Volt A/B/C
GridFreq:50.0Hz
AC VA/Watt:
230V/230V/230V
Once
Power Rate: 20%
P_Factor: 1.0
Double
Once
Once
COM Addr:
Date:2012/04/05
AC V Control:
003
Time: 14:20:38
Once
Double
Once
SerNo:
Model:
PR34200090
PV0000F161
DH 1.0–DH 0.0
Once
Build:dhaa-0101
Once
Double
Once
1 AC F Outrange
1 AC F Outrange
1 AC F Outrange
AC F:48Hz
Date:2016/04/06
Time:14:20:30
Once
Once
Once
2 AC V Outrange
2 AC V Outrange
2 AC V Outrange
Date:2016/04/06
Time:14:20:30
AC V:20.2V
Next page

Power on display

After inverter restarts, the background light will last for 2 seconds. You can check the
inverter series number, model, firmware version. Refer Fig6.3.1.
003
English
Disable
6.3.4 Operate by knock
VA W
Knock type and definition
The inverter can support four kinds of knock: single knock, double knock, third
Knock, Knock four times. Each kind of knock has different function. Refer to
specified definition in Table 6.3.2.
Enable
FW Version:
FW Version:
Light backlight and single knock to check running information
Before light the backlight, the four types of knock functions are the same, which is
just lighting the backlight. Note that the background lighting will automatically turn
off if there is no knock detected in 10 seconds.
During cloudy days or in the area of low light, it's inconvenient for users to check
inverter running information such as status, input data, output data, energy
generated. In this case user can light the backlight and check those data by single
knock, a single knock will switch LCD screen to a following interface.
Growatt
PV Inverter
SerNo:
PR34200090
Model:
PVBC00F161
FW Version:
DH 1.0–DH 0.0
Fig6.3.1Power on display
Table 6.3.2 Knock definition list
Knock type
Definition
Single knock
Down
Double knock
Enter
Three knock
Make sure setting
Knock four times
Back to cycle display interface
32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents