IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC
outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
A. Mounting
The K-1275 is designed to be installed in a sheltered location, and is not meant to be used outdoors. For outdoor
applications use the K-1275-EWP. The K-1275 can either be installed as a flush mount unit using the included
rough in box, or as a surface mount unit using an optional VE-5x10. The rough in box uses the inner set of four
holes on the face plate while the VE-5x10 uses the outside set of holes. A set of dummy screws and nuts are
provided to fill the unused mounting holes.
Front View
of the K-1275-IP
5.00"
4.50"
2.596"
0.952"
10.0"
1
1
2
2
9.5"
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
*
*
#
#
VIKING
©
14 Gauge Marine
Grade 316 Stainless
Steel Faceplate
B. Changing the Directory
To install a directory, remove the four screws that mount
the directory lens to the front of the K-1275 using the
included Allen wrench. Insert a paper directory behind the
lens and secure the two back onto the front panel being
careful to align the names with the front panel graphics.
For your convenience, the back of this document has pre-
printed directory forms.
Note: To print directory forms for the K-1275, go to
www.vikingelectronics.com and enter "930" in the DOD
field at the top of the page for a direct link to the PDF.
C. Wiring
The K-1275 can be powered from any source supplying 12
to 24 volts, AC or DC. A 12 volt DC adapter is supplied with
the product. When using the included adapter, the plug on
the adapter cord will have to be removed. The power
connections to the K-1275 (black wires) are not polarity
sensitive.
There are also 8 more wires connected to the K-1275
controller board. Two wires are for the incoming phone line,
three are from the high current door strike relay and the last
three are from the camera relay. Gel filled butt connectors
are provided for easier connection to building wiring. The
table at the right describes each wire's function.

Installation

Side View
of the K-1275-IP
0.425"
8.65"
(8) #6-32 x 3/4" Stainless
Steel, T-10 Torx Security
Screws with drive bit
(included)
Optional VE-5x10 Surface Mount
Box (not included), see DOD# 424
2.5"
4.5"
9.12"
- OR -
Zinc-Plated Steel
Rough-In Box
(included)
Paper Directory
Directory
Lens
Color
Black
Black
Green
Red
Brown
Orange
Yellow
Blue
Violet
White
3.69"
5.22"
Function
Power In
Power In
Phone Line In
Phone Line In
Door Strike Relay common
Door Strike Relay NC
Door Strike Relay NO
Camera Relay common
Camera Relay NC
Camera Relay NO