A. Mounting
The K-1270-IP is designed to be installed in a sheltered location, and is not meant to be used outdoors. For outdoor
applications use the K-1270-IP-EWP. The K-1270-IP can either be installed as a flush mount unit using the included
rough in box, or as a surface mount unit using an optional VE-5x10 or VE-5x10-SS. The rough in box uses the inner
set of four holes on the face plate while the VE-5x10 uses the outside set of holes. A set of dummy screws and nuts are
provided to fill the unused mounting holes. Note: Write down the MAC Address (found on the RJ-45 jack) as this may
be needed to identify the unit after installation.
Front View
5.00"
4.50"
2.596"
0.952"
10.0"
1
1
2
2
9.5"
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
*
*
#
#
VIKING
©
14 Gauge Marine Grade 316
Stainless Steel Faceplate
B. Changing the Directory
To install a directory, remove the four screws that
mount the directory lens to the front of the K-1270-IP
using the included Allen wrench. Insert a paper
directory behind the lens and secure the two back onto
the front panel being careful to align the names with
the front panel graphics.
Note: To print directory forms for the K-1270-IP, go to
www.vikingelectronics.com and enter "930" in the DOD
field at the top of the page for a direct link to the PDF.

Installation and Mounting

Side View
0.425"
8.65"
(8) #6-32 x 1/2" Stainless
Steel, 5/64" T-10 Torx
Security Screws (included)
Earth Ground the
Green/Yellow wire
using the
provided wire nut
2.5"
4.5"
9.12"
- OR -
Zinc-Plated Steel
Rough-In Box
Earth
(included)
Ground
Paper Directory
Directory
Lens
5
3.69"
5.22"
10.14"
Optional VE-5x10
Surface Mount Box
(not included), see DOD# 424