Operation - Viking K-1270-IP Series Product Manual

Vandal resistant voip entry phone system with built-in directory, 12 button auto dialer & proximity card r eader
Table of Contents

Advertisement

40. Clear Unit Settings
Clicking on the "Clear Unit settings" button in programming will reset all of the Programming Features back to their
factory default settings. Note: This command will not change or reset your IP settings.
41. Clear IP Settings
Clicking on the "Clear IP Settings" will reset all of the IP settings back to their factory default settings. This also clears
paging Group settings and Addresses. Note: This will not effect any speaker or paging settings.
42. Diagnostics
The Diagnostics section in the Viking IP Programming can be used to test the functionality of the two relays, read
current relay status, perform mic/spkr diagnostics, or to display information on the last card or fob detected by the card
reader.
43. REX Input
The K-1270-IP has one Request for Exit (REX) trigger input. The REX switch must have a momentary, normally open contact.
When the K-1270-IP detects a contact closure on the REX trigger input it performs one of the following actions, based on the Relay
Mode settings for each relay (see section 22):
Relay 1 "Door Strike", relay 2 other: Relay 1 will be activated for the programmed Relay 1 Activation Time.
Relay 1 other, relay 2 "Door Strike": Relay 2 will be activated for the programmed Relay 2 Activation Time.
Relay 1 "Door Strike", relay 2 "Door Strike": If the Relay Activation Delay is disabled, Relay 2 will be activated for the programmed
Relay 2 Activation Time. If Relay Activation Delay is not disabled, Relay 2 will be activated for the programmed Relay 2 Activation
Time, then after the Relay Activation Delay time has passed, Relay 1 will be activated for the programmed Relay 1 Activation Time.
This is useful in two door vestibule applications where Relay 1 is used to unlock the outside door, and Relay 2 is used to unlock the
inside door.
NOTE: For security reasons this input is disabled when the relay is set to "External".
A. Keypad
When a Keypad button is pressed, the K-1270-IP immediately dials the pre-programmed telephone number stored in
the corresponding Phone Number Database Index location (1-#). The Call Status LED momentarily flashes during
dialing. In the event the line is busy or there is a ring-no-answer, the unit can be programmed to call a second roll over
number.
When the call is answered, relay activation commands can be entered or the # key can be used to force the phone to
hang-up.
After communication is established, enter the 1 or 2 digit relay activation command (factory set to "QQ"
) to momentarily activate the entry phone (door strike) relay. Two beeps will be heard confirming that the
"Q2" for Relay 2
relay has been activated. If you require the relay to remain on continuously (ie: a truck delivery), enter Touch Tones
"11" or "21" to continuously activate relay 1 or relay 2 respectively. A double beep will indicate that the relay is latched
on. When the visitor calls in again (ie: they are finished unloading the truck), enter Touch Tones "10" or "20" to deactivate
relay 1 or relay 2 respectively. A single beep will indicate the relay is latched off. The relays can be toggled by entering
"1#" and "2#" for relays 1 and 2.

Operation

20
for Relay 1 and

Advertisement

Table of Contents
loading

This manual is also suitable for:

K-1270-ipK-1270-ip-ewp

Table of Contents