C. Auto-Answer Feature (DIP Switch 7)
With DIP switch 7 in the "ON" position (default), the K-1700-3 will automatically answer the line during the first incoming ring. This
feature is useful for monitoring entrances. In the "OFF" position, the K-1775-3 will not automatically answer incoming calls.
D. Push Button Hang Up (DIP Switch 8)
With DIP switch 8 in the "ON" position (default), the "Call" button alternately connects and disconnects calls. In the "OFF" position,
the "Call" button is only used to connect and the K-1775-3 must rely on call progress (busy, return to dial tone, silence time-out, or
maximum call time) for an automatic disconnect.
E. VOX (Talk/Listen) Switching Speed (DIP Switch 4)
With DIP switch 4 in the "OFF" position (default), the VOX switching speed (delay time between talk and listen mode) is set to fast
(0.2 seconds). In the "ON" position, it is set to slow (0.7 seconds).
F. Advanced Call Progress Detection
The K-1770-3 will output 3 beeps and automatically hang-up after detecting any of the following: busy signal (standard or fast/reorder),
CPC (short break in line current when called party hangs up), return to dial tone, maximum call time or silence time out.
When the push button is pressed, the K-1775-3 phone goes off-hook, much like a standard speaker phone. The
keypad may then be used to dial any number. In the event that the line is busy, the K-1775-3 will hang-up. The
K-1775-3 will also automatically hang up on CPC, silence, busy signal, return to dial tone or time out. If programmed
to auto-answer (DIP switch 7 ON), the K-1775-3 will also answer any incoming call.
The K-1775-3 color video camera operates completely independently of the K-1775-3 phone board. With power
supplied to the camera, it will continuously output a video signal.
The K-1775-3 proximity card reader operates completely independently of the K-1775-3 phone board. When
connected to an Viking ES-1 or C-4000 (or equivalent card reader controller) the red LED will light, indicating the card
reader is powered. The LED will turn off and the transducer will beep indicating a card scan.
A. C-500 Advanced Two Door/Gate Entry Phone Controller with Call Forwarding
The C-500 allows up to 2 entry phones (expandable to 8 entry phones, see DOD 177) to call into your existing
residential or business phones or phone system. Tenants may answer the call, converse with the visitor and activate
a contact closure to control electronic gates or door strikes. The C-500 provides user programmable entry phone,
"Caller ID," and "Call Waiting" tone when the phone line is in use. The C-500 also has built in five number dialer to
call your cell phone or an outside line if there is no answer on the inside phone. If the outside call is busy or ring no
answer, the C-500 can call up to four more numbers. Tenants may gain entry at each gate by entering a Touch
Tone keyless entry code. Tenants may call out to each entry phone for monitoring purposes. An auxiliary input is
also available for connecting a common garage door opener/receiver and auxiliary keyless entry keypads.
120V AC
13.8V AC
Adapter
included
Analog Trunk /
Line Input of a
Phone System
C.O. / Phone
Line Input
|
OR
|
Entry Phone 1
Model K-1700-3-BN shown,
not included (see DOD 157)
Standard
Analog Phone(s)

Operation

Applications
VIKING
©
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED 2 DOOR ENTRY PHONE
CONTROLLER WITH CALL FORWARDING
1 2 3 4 5 6
7 8 9
10 11 12
R
E
X
1
120V AC
Door Strike /
Magnetic Lock 1
MODEL C-500
+
13 14
15 16 17
18
19
R
E
X
2
5A@30VDC/250VAC max
(Power typically not required
for gate controllers)
6
Model C-500 (not included)
For more information on the
C-500, see DOD 177.
Control Output to
SLP-1 or SLP-4
120V AC
Door Strike /
Magnetic Lock 2
Entry Phone 2
Model K-1775-3 shown
(set Dip switch 3 to OFF)
5A@30VDC/
250VAC max
(Power typically
not required for
gate controllers)