G. Call Length Time Out
This feature selects the maximum length of time that calls can be connected. Programmable in
increments of 1 minute up to a maximum of 9 minutes. To disable the call length time out, program ten
ones in the "Time" value location. With the call length disabled, the E-60 phone must rely on CPC,
busy, silence or return dial tone to hang-up. Use the chart at the right. * Note: The factory default is
5 minutes.
H. Silence Time Out
This feature selects the length of time that calls will remain connected without voice activity.
Programmable in increments of 10 seconds up to a maximum of 90 seconds. To disable the silence
time out, program ten ones in the "Time" value location. Use the chart at the right. * Note: The factory
default is 40 seconds.
Time
Value
1
11
111
1111
11111
111111
1111111
11111111
111111111
10 OR MORE
I. Talk/Listen Delay (VOX Switching Speed)
This feature selects switching time between talk/ listen modes (VOX switching time). Use the
chart above. * Note: The factory default is .3 sec.
When the push button is pressed, the E-60 phone goes off-hook, much like a standard speaker phone.
In the event that the line is busy, the E-60 will hang-up. The E-60 will also automatically hang up on
CPC, silence, busy signal, return to dial tone or time out. If programmed to auto-answer (DIP switch 1
ON), the E-60 will also answer any incoming call.
Table A
Call length
Time Out
1 min
2 min
3 min
4 min
5 min*
6 min
7 min
8 min
9 min
Disabled

Operation

Silence
Time Out
10 sec
.20 sec
.30 sec
.40 sec*
50 sec
60 sec
70 sec
80 sec
90 sec
Disabled
Talk/Listen
Delay
.1 sec
.2 sec
.3 sec*
.4 sec
.5 sec
.6 sec
.7 sec
.8 sec
.9 sec
Error