Remote Station; Over View - Furuno FS-1562 Manual

Hide thumbs Also See for FS-1562:
Table of Contents

Advertisement

1. Over view

Connection of Remote Unit
A radiotelephone is connected to a remote unit, such as remote terminal, DSC, and NBDP
in Furuno MIF format of which TX/RX data lines are heard-wear selectable for current
loop or RS-232C signal.
Maximum four remote units can be connected by using a distributor DB-500 as shown in
Figure below.
Each port on the DB-500 can support Current loop and RS-232C signals according to the
type of the REMOTE board fitted in the DB-500: REMOTE A board for RS-232C and
REMOTE B board for Current loop. Each port has own REMOTE board.
The remote unit ports on the DB-500 have priority;
REM-2 > REM 3 > REM-4 > REM 5
There are two types of the DB-500.
DB-500: Standard type
REMOTE-1 (IN) ----- C.Loop (REM B)
REMOTE-2 (OUT) ----- C.Loop (REM B)
REMOTE-3 (OUT) ----- C.Loop (REM B)
DB-500-RS type
REMOTE-1(IN)
REMOTE-2(OUT) ----- RS-232C (REM A)
REMOTE-3(OUT) ----- C.Loop (REM B)
REMOTE-4(OUT) ----- C.Loop (REM B)
REMOTE-5(OUT) ----- RS-232C (REM A)
Section I1. Remote Station
REMOTE
TX/RX Control data
REM-A
RS-232C
FS-xxxx
FS-1562
REM-A
RS-232C
DB-500
REM-A
REM-A
REM-B
[REM2]
[REM3]
RS-232C
C.Loop
DSC-6/60
RB-500
----- RS-232C(REM A)
I1-1
REMOTE
DSC/NBDP
RS-232C
[REM1]
REM-B
REM-A
[REM4]
[REM5]
C.Loop
RS-232C
RB-500
DP-5/6

Hide quick links: