7. NBDP PORT (Default setting: OFF)
If FS-75/1562 or FS-5000 series is connected to Furuno NBDP, DP-5/6, set this item at
ON. Then, the control of the NBDP can be made by the MIF protocol.
Whereas MAIN and MODEM CPU programs are updated from IB-581 or PC, NBDP
Port setting is disregarded. At this time, however, set DIP switch S3-1 and 2 at ON, S3-3
and 4 at OFF.
Note) Related settings
Select RS-232C, RS-422, or Current Loop by DIP switches S3 and S5 on
CONTROL/MODEM board.
The pin assignment of NBDP connector for MIF data is different from those for IEC data.
When DP-6 or DP-5 is connected, set DIP switch as below.
- S3-#1 and #2: ON
- S3-#3 and #4: OFF
8. CH DET S LEVEL (Default setting: 100)
Before transmitting Routine and Business message, the system checks whether the
frequency to be transmitted is already in use or not. If it is used, the transmission is
commenced after the channel is not used.
corresponds to 255. To deactivate this function, select OFF.
9. REGULATION (Default setting: INTL) Main Ver 2.09 and after
In Russian version;
- Alarm is released continuously after transmitting distress alert.
- The [CANCEL] key can be used during the transmission of distress alert.
The transmission sequence is stopped at the end of the fifth transmission.
- If another distress alert or urgent message is received after pressing the [CALL] key for
distress relay or distress acknowledgement, the received message has priority while the
function triggered by the [CALL] key is cancelled.
10. DIST
Date and time of the latest distress alert are displayed. The data is stored onto the
EEROM. Main Ver 2.01: Date and time in ZDA is used. If ZDA is not available, XXXX
is shown. Main Ver 2.09: ZDA or RMC is used. If ZDA or RMC are not input, XXXX is
shown.
Main Ver 2.09 and after
The maximum scale of the S-meter
B4-5
DSC60