How to set OID/DID for HSD
After the modification of the communication unit for the HSD, the OID/DID for
the HSD communication must be set by using the following procedure.
1. Press [F4] [6] to display the Communication Unit Setup menu.
2. Type "FURUNOSERVICE" as the Job No.
3. Press [Enter] key.
4. Type "FELCOM81" as the password.
5. Press [Enter].
6. Press [6] [Enter] to display the commissioning menu.
7. Press [6] [Enter] to display the OID/DID registration menu.
8. Press [9] for HSD ID registration.
9. Enter the ID(s) assigned by the organization for the HSD64 and/or HSD56
communication.
Set the telephone terminal number to be used for HSD call. In the example
10.
below, No.3 telephone is used for HSD call.
If provided, the DTMF (Dial Tone Multi Frequency) signal from the HSD
terminal can be connected to the telephone terminal on the communication unit
IB-281. In this case, the telephone number to be used must be entered on the
HSD ID line, but the OID/DID setting for the telephone is not required. If the
DTMF signal is not connected to the communication unit and is not provided, no
telephone number is entered on the HSD ID line and the No.1 telephone is used
for the HSD calling.
In the example below, the OIDs/DIDs for the HSD56 and the HSD64 are 41 and
51 respectively. The DTMF signal from the HSD terminal is connected to the
No.3 telephone terminal, that is, the calling from the HSD terminal is made by
using the No.3 telephone line. Note that no ID is entered on the No.3 TEL/FAX
line.