DSC-5
3. Jumper wire settings
DSC-5A only
Format
JP 1
JP 2
CIF (default)
Open
Short
NMEA
Short
Open
Note)
CIF/NMEA selection must be also made through the menu;
Select the PROG menu and call the COMM menu, then select CIF/NMEA selection
mode. (COMM menu can be called only when "Ignore ID" is set to "ON" .)
B1-8