Secton 8 - Emergency Systems and Procedures
Emergency Systems and Procedures
Emergency Systems and Procedures
Emergency Stop
ART_3353
Emergency Lowering
The Emergency Lowering System is used to lower the platform in case of
power failure.
To lower the platform, pull the Emergency Lowering Knob, located near
the Base Control panel.
Page 11
IF THE CONTROL SYSTEM FAILS WHILE THE PLATFORM IS ELEVATED,
HAVE AN EXPERIENCED OPERATOR USE THE EMERGENCY LOWERING
PROCEDURE TO SAFELY LOWER THE PLATFORM.
DO NOT ATTEMPT TO CLIMB DOWN ELEVATING ASSEMBLY.
The machine is equipped with an EMERGENCY STOP switch at the base
controls and the platform control box.
•
Press the EMERGENCY STOP switch at any time to stop all machine
functions.
•
Pull switch to reset.
•
Either switch will stop all machine functions.
•
Both switches must be reset or machine will not operate.
IF THE CONTROL SYSTEM FAILS WHILE THE PLATFORM IS ELEVATED,
USE THE EMERGENCY LOWERING PROCEDURE TO SAFELY LOWER
THE PLATFORM.
DO NOT CLIMB DOWN THE ELEVATING ASSEMBLY OR EXIT THE
PLATFORM.