Basic Alarm Configuration

Launching the Basic Alarm Application

You can access the Basic Alarm application in one of two ways:
from the Hub View:
1. If necessary, put the Hub View into the Interface Application Display mode
2. Click either mouse button on the Display Mode box to launch the Interface
from the command line (stand-alone mode):
1. From the appropriate directory type:
The spmarun script invoked first in the above command temporarily sets the environment
variables SPMA needs to operate; be sure to use this command any time you launch an
NOTES
application from the command line. This script is automatically invoked when you launch
an application from within the Hub View.
If you wish to configure alarms via the Basic Alarm Configuration window, be sure to use
a write community name with at least Read/Write access. If you only wish to view
alarms, a community name with Read access will be sufficient.
If there is a hostname mapped to your 7C0x's IP address, you can use <hostname> in
place of <IP address> to launch this application. Please note, however, that the hostname
is not the same as the device name which can be assigned via Local Management and/or
SPMA; you cannot use the device name in place of the IP address.
If you launch the Basic Alarm application (whether from the Interface menu in the Hub
View or from the command line) against a 7C0x whose RMON MIB component has been
TIP
disabled, an error window will appear notifying you of that fact.
In many cases the RMON component is disabled by default when the device is shipped; to
enable it, use the MIBTree or any similar SNMP-based MIB tool to query the
contLogicalEntryTable, and change the contLogicalEntryAdminStatus value for the
RMON component from 7 (disabled) to 3 (enabled). The application should then run
successfully.
3-2
(click either mouse button on the Module Index or Module Type box to display
the Module menu, drag down to Application Display, then right to select
Interface).
menu; drag down to Basic Alarm Configuration, and release.
spmarun balarm <IP Address> <read community name>
<write community name>
About Basic Alarms