Cabletron Systems 7C04 Workgroup SmartSWITCH User Manual

Cabletron systems user's guide smartswitchtm 7c04 workgroup
Hide thumbs Also See for 7C04 Workgroup SmartSWITCH:

Advertisement

Quick Links

7C04 Workgroup
SmartSWITCH
Chassis
User's Guide
9031700-01

Advertisement

Table of Contents
loading

Summary of Contents for Cabletron Systems 7C04 Workgroup SmartSWITCH

  • Page 1 7C04 Workgroup ™ SmartSWITCH Chassis User’s Guide 9031700-01...
  • Page 2 The hardware, firmware, or software described in this manual is subject to change without notice. In no event shall Cabletron Systems be liable for any incidental, indirect, special, or consequential damages whatsoever (including but not limited to lost profits) arising out of or related to this...
  • Page 3: Fcc Notice

    Notice FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 4 Notice VCCI NOTICE This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference (VCCI) by Information Technology Equipment aimed at preventing radio interference in commercial and/or industrial areas.
  • Page 5: Table Of Contents

    CHAPTER 1 INTRODUCTION 1.1 USING THIS MANUAL ...1-1 1.2 USING THE SMARTSWITCH MANUAL SET ...1-1 1.3 CHASSIS OVERVIEW...1-2 1.3.1 7X00 SmartSwitch Controller Module ...1-3 1.3.2 SmartSwitch interface modules ...1-3 1.3.3 Operations...1-4 1.4 SITE GUIDELINES ...1-5 1.5 RELATED MANUALS...1-6 1.6 GETTING HELP...1-6 CHAPTER 2 INSTALLATION 2.1 UNPACKING THE 7C04 CHASSIS ...2-1 2.2 INSTALLING THE 7C04 CHASSIS IN AN EQUIPMENT RACK ...2-2...
  • Page 6: Chapter 1 Introduction

    Welcome to Cabletron Systems 7C04 Workgroup SmartSwitch Chassis User’s Guide. This manual describes the physical characteristics, specifications, and capabilities of the 7C04 Workgroup SmartSwitch Chassis. 1.1 USING THIS MANUAL Chapter 1, Introduction Chassis. Chapter 2, Installation module, and how to install that power supply module.
  • Page 7: Chassis Overview

    (slot one). The other three slots can support nearly any combination of Ethernet, Token Ring, FDDI, and ATM SmartSwitch interface modules Figure 1-1. 7C04 Workgroup SmartSwitch Chassis Data from each SmartSwitch interface module (regardless of front panel technology) is relayed along the SmartSwitch Bus on the 7C04 Chassis’...
  • Page 8: 7X00 Smartswitch Controller Module

    SmartSwitch Core is capable of switching up to 750,000 frames per second. The firmware on a 7X00 Module determines the SmartSwitch Core’s operating mode (traditional switch or SecureFast Packet Switch). The module’s CPU (an i960 ® microprocessor ) is used to collect management data of the SmartSwitch system (including the status of the chassis’...
  • Page 9: Operations

    SecureFast Packet Switch When operating as a SecureFast Packet Switch, the 7X00 Module’s SmartSwitch Core searches for the frame’s destination address- source address (DA-SA) pair and receive port in the module’s connection table.
  • Page 10: Site Guidelines

    If the frame’s entry is not found in the connection table, a request is sent to the system’s Virtual Network Services (VNS). The VNS checks its virtual routing tables and policy sections. If the frame’s information appears in the VNS’ virtual routing tables and the VNS’...
  • Page 11: Related Manuals

    (module specific). Cabletron Systems SmartSwitch Interface Module Local Management Appendices (module specific). Cabletron Systems 7X00 SmartSwitch Controller Module User’s Guide 1.6 GETTING HELP If you need additional support with the 7C04 Chassis, or if you have any questions, comments or suggestions concerning this...
  • Page 12: Chapter 2 Installation

    Set the chassis aside. 3. Remove the accessory package and verify that it contains two mounting brackets. 4. Examine the chassis (and brackets) and check for damage. If damage exists, contact Cabletron Systems Technical Support. CHAPTER 2 INSTALLATION...
  • Page 13: Installing The 7C04 Chassis In An Equipment Rack

    Installation 2.2 INSTALLING THE 7C04 CHASSIS IN AN EQUIPMENT RACK The following section details the process of attaching mounting brackets to the 7C04 Chassis, and installing the chassis in a standard 19-inch equipment rack. If you are not installing the chassis in an equipment rack, skip to Section 2.3.
  • Page 14 7. Align the two round holes of the left mounting bracket with the holes (from which you removed the screws) on the left side of the chassis. 8. Insert the screws that you removed in step 6 into the holes on the bracket and chassis.
  • Page 15: Mounting The 7C04 Chassis

    Installation 2.2.2 Mounting the 7C04 Chassis To mount the 7C04 Chassis in a standard 19-inch equipment rack, (Figure 2-2) use the following steps: 1. Slide the chassis into the equipment rack. 2. Align the holes on the chassis’ mounting brackets with the holes on the equipment rack.
  • Page 16: The 7C04 Chassis Power Supply Module

    3. Examine the power supply module and check for damage. If damage exists, DO NOT install the power supply module; contact Cabletron Systems Technical Support. Otherwise, install the power supply module (see Section 2.3.2). 2.3.2 Installing the Power Supply Module To install a power supply module in the 7C04 Chassis, use the following steps and refer to Figure 2-3.
  • Page 17 Installation 3. Align the notch on the top of the power supply module with the semi-circular tab in the top center of the power supply module cavity of the chassis. Figure 2-3. Installing the power supply module into a 7C04 Chassis 4.
  • Page 18: Powering Up The Power Supply Module

    2. Plug the power cord into an electrical outlet. 3. Locate the power switch on the lower portion of the power supply module’s front panel. The power switch has two settings: O for off, - for on.
  • Page 19: Removing The Power Supply Module

    To remove the power supply module from the chassis, refer to Figure 2-4 and proceed as follows: 1. Press the power supply’s power switch to the off position (O). 2. Unplug the power cord from the power supply and from the electrical outlet.
  • Page 20: Chapter 3 Troubleshooting

    The front panel of the power supply module of the 7C04 Chassis (Figure 3-1) contains four LANVIEW LEDs to assist you in troubleshooting the power supply. The color of each LED and the course of action to pursue are detailed in Table 3-1 through Table 3-4.
  • Page 21 Make sure the power supply’s power switch is in the On (-) position. Make sure the power supply’s power cord is securely plugged into the...
  • Page 22 Table 3-3. OVERLOAD LED LED Color Green Normal operation The modules within the chassis are attempting to draw an amount of DC power that exceeds the power supply’s maximum DC power output. LED Color Green Normal operation One (or both) of the power supply’s fans has failed.
  • Page 23: Chapter 4 Technical Specifications

    TECHNICAL SPECIFICATIONS This chapter includes the technical specifications for Cabletron Systems 7C04 Chassis. Cabletron Systems reserves the right to change these specifications at any time without notice. 4.1 SAFETY It is the responsibility of the person who sells the chassis to ensure that the total system meets allowed limits of conducted and radiated emissions.
  • Page 24: Service

    Technical Specifications 4.4 SERVICE MTBF: MTTR: 4.5 POWER AC Input: DC Output: Fusing: 4.6 PHYSICAL 4.6.1 Dimensions 34.8 D x 16.0 H x 43.2 W centimeters (13.7 D x 6.3 H x 17.0 W inches) 4.6.2 Weight Unit: Shipping: >200,000 hours <0.5 hour 100 - 125 volts, 3.8 amps 200 - 250 volts, 1.9 amps...
  • Page 25: Environmental

    4.7 ENVIRONMENTAL Operating Temperature: +5 to +40 C (+41 to +104 F) Storage Temperature: Relative Humidity: Technical Specifications -30 to +90 C (-22 to +194 F) 5 to 95% (non-condensing)

Table of Contents