You can use the COM Port Configuration window to set the following operating
parameters:
COM Port Admin
Use this field to administratively enable or disable the COM port.
COM Port Function
Use this field to select the function for which you wish to use the COM port:
LM
UPS
SLIP
PPP
Managing the Hub
Figure 2-18. COM Port Configuration Window
Local Management: select this option if you wish to connect a
terminal to the selected COM port from which to run Local
Management.
Select this option if you wish to connect an uninterruptable
power supply (UPS) to the selected COM Port. Note that if you
select this option, an additional option — UPS — will appear on
the COM Port menu; use the resulting window to configure
specific UPS settings.
Select this option to use the selected COM port as a SLIP
connection for out-of-band SNMP management via direct
connection to a serial port on your network management
workstation. Note that when you configure the port as a SLIP
connection, you must select the desired baud rate in the Speed
Selection field described below.
Select this option to use the selected COM port as a PPP
connection for out-of-band SNMP management via direct
connection to a serial port on your network management
workstation. Note that when you configure the port as a PPP
connection, you must select the desired baud rate in the Speed
Selection field described below.
Using the 7C0x SmartSwitch Hub View
2-37