Using the 7C0x SmartSwitch Bridge View
Destination Port
Displays the port or ports to which frames that have the specified source address
and were received on the specified port or ports will be forwarded. Note that
packets with the specified source address received on the specified port or ports
will be blocked from any ports not listed in this field.
If the number of Destination Ports exceeds what the Destination Ports column is
able to display, Destination Ports for that filter appear as a hex string that maps to
actual port numbers.
For example, a Destination Port entry of B54180E0 represents ports 1, 3, 4, 6, 8, 10,
16, 17, 25, 26, and 27. Here's how to translate the hex string to port numbers:
1. Translate each hex integer into a four-digit binary value:
2. Each "1" in the binary bitmask represents a Destination Port number:
Status
Indicates the assigned permanence of the entry:
The buttons at the bottom of the window provide the following functions:
The Delete button is only available when the Filtering Database window is
showing Static entries and one entry in the list is selected. Use the Delete button to
remove an entry from the Static Table; see Deleting a Static Table Entry,
page
The Change button is only available when the Filtering Database window is
showing Static entries and one entry in the list is selected. Use the Change button
to change the selected port's receive port/destination ports settings; see
Changing Forwarding and Static Database Entries,
The Add to Static Table button is only available when the Filtering Database
window is showing Forwarding entries and one entry in the list is selected. Use it
to add a forwarding entry to the static database. Since the Forwarding table
cannot be edited, you must add an entry to the Static Table in order to change or
delete it, as desired.
6-16
B
5
4
1011
0101
0100
B
5
4
1011
0101
0100
1,X,3,4 X,6,X,8
X,10,X,X X,X,X,16 17,X,X,X X,X,X,X
permanent—The entry won't be aged out or deleted on reset.
deleteOnReset—The entry will be deleted when the bridge is reset.
deleteOnTimeout—The entry is subject to the ageing timer.
6-19.
1
8
0
0001
1000
0000
1
8
0
0001
1000
0000
page
The Filtering Database Window
E
0
1110
0000
E
0
1110
0000
25,26,27,X X,X,X,X