Chapter 2: Installation Requirements and Specifications
2.2

CONFIGURATION GUIDELINES

The 6C105 has 5 slots that accept interface modules. The slots are
numbered 1 to 5 beginning from the left. There are two additional slots
located on the far right of the chassis that are reserved for power supply
modules. These slots are labeled PS1 and PS2. Cabletron Systems
modules for the 6C105 are equipped with a firmware-based management
tool called Local Management, which provides the capability to configure
the module, and access chassis, power supply, and fan tray information.
These modules are also SNMP compliant to allow remote management
through SNMP software such as the Cabletron Systems SPECTRUM for
Open Systems suite of management products.
2.3

OPERATING SPECIFICATIONS

The following lists the specifications for the 6C105 chassis, 6C405 fan
tray and the 6C205-1, 6C205-2 and 6C205-3 power supplies. Cabletron
Systems reserves the right to change these specifications without notice.
Environment
Operating Temperature:
Storage Temperature:
Operating Relative Humidity:
Regulatory Compliance
Safety:
Electromagnetic
Compatibility (EMC):
2-2
5°C to 40°C (41°F to 104°F)
-30°C to 73°C (-22°F to 164°F)
5% to 90% (non-condensing)
UL 1950, CSA C22.2 No. 950,
EN 60950, 73/23/EEC, and IEC 950
FCC Part 15,VCCI V-3, CSA C108.8,
EN 50082-1, 89/336/EEC, and
EN 55022