Installing The Switch In A 19-Inch Rack; Installation Requirements; Mounting Brackets - H3C S5800-EI Series Installation Manual

Hide thumbs Also See for S5800-EI Series:
Table of Contents

Advertisement

Installing the switch in a 19-inch rack

Installation requirements

Table 3 Installation requirements for the S5800-EI switches
Installation
method
Using the front
and rear mounting
brackets
Figure 2 Rack-mounting procedure by using the front and rear mounting brackets
NOTE:
If a rack shelf is available, you can put the switch on the rack shelf, slide the switch to an appropriate
location, and attach the switch to the rack by using the mounting brackets.

Mounting brackets

The switch is provided with front mounting brackets with M4 screws (see
brackets with shoulder screws (see
Figure 3 Front mounting bracket
(1) Hole for attaching the bracket to a rack
Installation requirements
Install the front mounting brackets at the power
module side or port side.
Install the rear mounting brackets as required by
the rack depth:
If the rack depth is in the range of 429 to 595
mm (16.89 to 23.43 in), orient the bracket arm
forward.
If the rack depth is in the range of 274 to 440
mm (10.79 to 17.32 in) and the distance from
the rear rack posts to the inner surface of the
cabinet door is longer than 153 mm (6.02 in),
orient the bracket arm backward.
Figure
4).
(2) Hole for attaching the bracket to the switch
6
Installation procedure
See
"Rack-mounting by
using the front and rear
mounting
brackets."
Figure
3) and rear mounting